636
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring port mirroring and monitoring
20
The both, in, and out parameters specify the traffic direction you want to monitor on the mirror port.
There is no default.
To display the port monitoring configuration, enter the show monitor and show mirror commands.
Monitoring an individual trunk port
You can monitor the traffic on an individual port of a static trunk group, and on an individual port of
an LACP trunk group.
By default, when you monitor the primary port in a trunk group, aggregated traffic for all the ports in
the trunk group is copied to the mirror port. You can configure the device to monitor individual ports
in a trunk group. You can monitor the primary port or a secondary port individually.
To configure port monitoring on an individual port in a trunk group, enter commands such as the
following.
PowerConnect(config)#mirror-port ethernet 2/6
PowerConnect(config)#trunk e 2/2 to 2/5
PowerConnect(config-trunk-2/2-2/5)#config-trunk-ind
PowerConnect(config-trunk-2/2-2/5)#monitor ethernet 2/4 ethernet 2/6 in
Traffic on trunk port e 2/4 will be monitored, and the monitored traffic will be copied to port e 2/6,
the mirror port.
Syntax: [no] mirror-port ethernet
<port>
[input | output]
Syntax: [no] config-trunk-ind
Syntax: [no] monitor ethernet
<port>
both | in | out
The
<port>
variable for mirror-port ethernet specifies the port to which the monitored traffic will be
copied. The
<port>
variable for monitor ethernet specifies the port on which traffic will be
monitored.
Specify the
<port>
variable in the following formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
The input or output parameters configure the mirror port exclusively for ingress or egress traffic. If
you do not specify one, both types of traffic apply.
The config-trunk-ind command enables configuration of individual ports in the trunk group. You
enter the config-trunk-ind command only once in a trunk group. After you enter the command, all
applicable port configuration commands apply to individual ports only.
NOTE
If you enter no config-trunk-ind, all port configuration commands are removed from the individual
ports and the configuration of the primary port is applied to all the ports. Also, once you enter the
no config-trunk-ind command, the enable, disable, and monitor commands are valid only on the
primary port and apply to the entire trunk group.
The both, in, and out parameters specify the traffic direction you want to monitor on the mirror port.
There is no default.
To display the port monitoring configuration, enter the show monitor and show mirror commands.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...