PowerConnect B-Series FCX Configuration Guide
407
53-1002266-01
Configuring a trunk group
12
The to keyword indicates that you are specifying a range. Specify the lower port number in the
range first, then to, then the higher port number in the range.
Deleting a static trunk group
Use the command in this section to delete a static trunk group.
NOTE
To delete an LACP trunk group, use the CLI command no link-aggregate active | passive.
To delete a trunk group, use no in front of the command you used to create the trunk group. For
example, to remove one of the trunk groups configured in the examples above, enter the following
command.
PowerConnect(config)#no trunk ethernet 1/1 to 1/2 ethernet 3/3 to 3/4
Syntax: no trunk ethernet <
port>
to
<port>
[ethernet
<port>
to
<port>
]...
The
<port>
variable specifies an individual port. Specify the
<port>
variable in the following
formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
You can enter the ethernet
<port>
parameter multiple times to specify a list.
The to keyword indicates that you are specifying a range of ports. Specify the lower port number in
the range first, then to, then the higher port number in the range.
Specifying the minimum number of ports in a static trunk group
You can configure Dell PowerConnect devices to disable all of the ports in a trunk group when the
number of active member ports drops below a specified threshold value. For example, if a trunk
group has 4 ports, and the threshold for the trunk group is 3, then the trunk group is disabled if the
number of available ports in the trunk group drops below 3. If the trunk group is disabled, then
traffic is forwarded over a different link or trunk group.
For example, the following commands establish a trunk group consisting of 4 ports, then establish
a threshold for this trunk group of three ports.
PowerConnect(config)#trunk e 3/31 to 3/34
PowerConnect(config-trunk-3/31-3/34)#threshold 3
In this example, if the number of active ports drops below three, then all the ports in the trunk
group are disabled.
Syntax: [no] threshold
<number>
•
<number> - Specify a threshold number from 2 (default) up to the number of ports in a trunk
group. The total number of threshold ports must be greater than 1.
NOTE
When using the no threshold command, it is not necessary to enter a number.
Configuration notes:
•
This feature is supported on static trunk groups only. It is not supported on LACP trunk groups.
•
When UDLD is enabled on a trunk port, trunk threshold is not supported.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...