896
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring MLD snooping
27
Modifying the wait time before stopping traffic when receiving a leave
message
You can define the wait time before stopping traffic to a port when the device receives a leave
message for that port. The device sends group-specific queries once per second to determine if any
client on the same port still needs the group. The value range is from 1 to 5, and the default is 2.
Due to the internal timer accuracy, the actual wait time is between n and (n+1) seconds, where n is
the configured value.
PowerConnect(config)#ipv6 mld-snooping leave-wait-time 1
Syntax: [no] ipv6 mld-snooping leave-wait-time
<num>
Modifying the multicast cache (mcache) aging time
You can set the time for an mcache to age out when it does not receive traffic. The traffic is
hardware-switched. One minute before an mcache is aged out, the device mirrors a packet of the
mcache to the CPU to reset the age. If no data traffic arrives within one minute, the mcache is
deleted. If you configure a lower value, the resource consumed by idle streams is quickly removed,
but packets are mirrored to the CPU more frequently. Configure a higher value only when data
streams are arriving consistently. The range is 60 to 3600 seconds, and the default is 60 seconds.
PowerConnect(config)#ipv6 mld-snooping mcache-age 180
Syntax: [no] ipv6 mld-snooping mcache-age
<num>
Disabling error and warning messages
The device prints error or warning messages when it runs out of software resources or when it
receives packets with the wrong checksum or groups. These messages are rate limited. You can
turn off these messages by entering a command such as the following.
PowerConnect(config)#ipv6 mld-snooping verbose-off
Syntax: [no] ipv6 mld-snooping verbose-off
Configuring the MLD mode for a VLAN
You can configure a VLAN for either the active or passive (default) MLD mode. The VLAN setting
overrides the global setting:
•
Active – In active MLD mode, a device actively sends out MLD queries to identify IPv6 multicast
groups on the network, and makes entries in the MLD table based on the group membership
reports it receives from the network.
•
Passive – In passive MLD mode, the device forwards reports to router ports which receive
queries. MLD snooping in the passive mode does not send queries. However, it does forward
queries to the entire VLAN.
To set the MLD mode for VLAN 20 to active, enter the following commands.
PowerConnect(config)#vlan 20
PowerConnect(config-vlan-20)#mld-snooping active
Syntax: [no] mld-snooping active | passive
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...