background image

(Revised 2011-09-28) 

 

 

 
 
 
 
 

 
 
 

 
 

1000 Series 

Gigabit Media Converter &  

Industrial Gigabit Ethernet Switch  

 

 

 

       

User Manual & 

Installation 

Guide

 

 

 
 
 
 

 

 
 

 

Содержание NTSFP-LX-40

Страница 1: ...Revised 2011 09 28 1 1000 Series Gigabit Media Converter Industrial Gigabit Ethernet Switch User Manual Installation Guide...

Страница 2: ...00BaseLX singlemode fiber switch 1003GX2 B Custom mix and match 1003GX2 switch 1005TX 5 port gigabit Ethernet switch Where YY is 10 for 10km max fiber segment length 40 for 40km max fiber segment leng...

Страница 3: ...ion contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchan...

Страница 4: ...a definite safety hazard WARNING If the equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on th...

Страница 5: ...Revised 2011 09 28 5 LASER SAFETY 1002MC and 1003GX2 Models CAUTION CLASS 1 LASER PRODUCT Do not stare into the laser...

Страница 6: ...C MCE is a two port unmanaged media converter that converts 10 100 1000Base T copper to 1000BaseSX LX full duplex fiber The 1003GX2 GXE2 is a three port unmanaged switch that offers one 10 100 1000Bas...

Страница 7: ...KING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following w...

Страница 8: ...it snaps into place To remove the unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up...

Страница 9: ...ty LED SPD1000 1000 Speed LED LEDs The table below describes the operating modes LED Color Description ON Power is Applied OFF Power is OFF LNK ACT ON Link established no Activity on cable BLINKING Li...

Страница 10: ...lug is 0 5 Nm 0 368 Pound Foot All LEDs will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation...

Страница 11: ...ve output terminal and the chassis grounding point of the switch As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a...

Страница 12: ...e straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROU...

Страница 13: ...cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian...

Страница 14: ...ipple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10...

Страница 15: ...m 0 45 dB km 0 35 dB km 0 25 dB km Laser Type VCSEL FP DFB DFB SX Fiber Optic Cable LX Fiber Optic Cable Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2007 US and Canada and listed for u...

Страница 16: ...le Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 00...

Страница 17: ...m 0 45 dB km 0 35 dB km 0 25 dB km Laser Type VCSEL FP DFB DFB SX Fiber Optic Cable LX Fiber Optic Cable Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2007 US and Canada and listed for u...

Страница 18: ...e Inrush Current 13 Amp 0 61 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 1...

Страница 19: ...and listed for use in Class I Div 2 Groups A B C D T4 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4...

Страница 20: ...RANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON...

Отзывы: