1396
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Syslog messages
41
Informational
Bridge root changed, vlan
<vlan-id>
, new
root ID
<string>
, root interface
<portnum>
A Spanning Tree Protocol (STP) topology
change has occurred.
The
<vlan-id>
is the ID of the VLAN in which
the STP topology change occurred.
The
<root-id>
is the STP bridge root ID.
The
<portnum>
is the number of the port
connected to the new root bridge.
Informational
Bridge topology change, vlan
<vlan-id>
,
interface
<portnum>
, changed state to
<stp-state>
A Spanning Tree Protocol (STP) topology
change has occurred on a port.
The
<vlan-id>
is the ID of the VLAN in which
the STP topology change occurred.
The
<portnum>
is the port number.
The
<stp-state>
is the new STP state and
can be one of the following:
•
disabled
•
blocking
•
listening
•
learning
•
forwarding
•
unknown
Informational
Cold start
The device has been powered on.
Informational
DHCP : snooping on untrusted port
<portnum>, type <number>, drop
The device has indicated that the DHCP
client receives DHCP server reply packets
on untrusted ports, and packets are
dropped.
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
Cannot apply an ACL or MAC filter
on a port member of a VE (virtual interface)
The RADIUS server returned an IP ACL or
MAC address filter, but the port is a
member of a virtual interface (VE).
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
cannot remove inbound ACL
An error occurred while removing the
inbound ACL.
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
Downloading a MAC filter, but MAC
filter have no effect on router port
The RADIUS server returned an MAC
address filter, but the
<portnum>
is a router
port (it has one or more IP addresses).
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
Downloading an IP ACL, but IP ACL
have no effect on a switch port
The RADIUS server returned an IP ACL, but
the
<portnum>
is a switch port (no IP
address).
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
Error - could not add all MAC filters
The Dell PowerConnect device was unable
to implement the MAC address filters
returned by the RADIUS server.
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
Invalid MAC filter ID - this ID
doesn't exist
The MAC address filter ID returned by the
RADIUS server does not exist in the Dell
PowerConnect configuration.
Informational
DOT1X : port
<portnum>
- mac
<mac
address>
Invalid MAC filter ID - this ID is user
defined and cannot be used
The port was assigned a MAC address filter
ID that had been dynamically created by
another user.
TABLE 239
Syslog messages (Continued)
Message level
Message
Explanation
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...