PowerConnect B-Series FCX Configuration Guide
651
53-1002266-01
IGMP snooping overview
22
The <
num
> value can be 4, 8, 16, or 32. Any other value is truncated to the closest lower ceiling.
For example, a value of 15 is changed to 8. The default hash chain length is 4. A chain length of
more than 4 may affect line rate switching.
NOTE
For this command to take effect, you must save the configuration and reload the switch.
The hardware resource limit applies only to the VLANs where IGMP snooping is enabled. Multicast
streams are switched in hardware without using any pre-installed resources in a VLAN where
snooping is not enabled.
PowerConnect B-Series FCX devices support up to 32K of IGMP groups, which are produced by
client membership reports.
Configuration notes
•
Servers (traffic sources) are not required to send IGMP memberships.
•
The default IGMP version is V2.
•
Hardware resource is installed only when there is data traffic. If a VLAN is configured for
IGMPv3, the hardware matches (S G), otherwise it matches (* G).
•
A user can configure the maximum numbers of groups and hardware switched data streams.
•
The device supports static groups that apply to the entire VLAN, or to just a few ports. The
device acts as a proxy to send IGMP reports for the static groups when receiving queries. The
static group has a drop option to discard multicast data packets in hardware.
•
A user can configure static router ports to force all multicast traffic to these specific ports.
•
The devices support fast leave for IGMPv2. Fast leave stops traffic immediately when the port
receives a leave message.
•
The devices support tracking and fast leave for IGMPv3, tracking all IGMPv3 clients. If the only
client on a port leaves, traffic is stopped immediately.
•
An IGMP device can be configured as a querier (active) or non-querier (passive). Queriers send
queries. Non-queriers listen for queries and forward them to the entire VLAN.
•
Every VLAN can be independently configured to be a querier or a non-querier.
•
If a VLAN has a connection to a PIM or DVMRP-enabled port on another router, this VLAN must
be configured as a non-querier (passive). When multiple snooping devices connect together
and there is no connection to PIM or DVMRP ports, one device must be configured as a querier
(active). If multiple devices are configured as active (queriers), only one will keep sending
queries after exchanging queries.
•
An IGMP device can be configured to rate-limit the forwarding IGMPv2 membership reports to
queriers.
•
The querier must configure an IP address to send out queries.
•
When VSRP or VSRP-aware is configured on a VLAN, the VLAN will support IGMP snooping
version 2 only. IGMP version 3 will not be supported on the VLAN.
•
When OSPF/PIM/VRRP is configured on a VLAN on the PowerConnect B-Series FCX , the VLAN
will support IGMP snooping version 1 and version 2. IGMP snooping version 3 will not be
supported on the VLAN.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...