PowerConnect B-Series FCX Configuration Guide
1393
53-1002266-01
Syslog messages
41
Alert
Management module at slot
<slot-num>
state changed from
<module-state>
to
<module-state>
.
Indicates a state change in a management
module.
The
<slot-num>
indicates the chassis slot
containing the module.
The
<module-state>
can be one of the
following:
•
active
•
standby
•
crashed
•
coming-up
•
unknown
Alert
OSPF LSA Overflow, LSA Type =
<lsa-type>
Indicates an LSA database overflow.
The
<lsa-type>
parameter indicates the
type of LSA that experienced the overflow
condition. The LSA type is one of the
following:
•
1 – Router
•
2 – Network
•
3 – Summary
•
4 – Summary
•
5 – External
Alert
OSPF Memory Overflow
OSPF has run out of memory.
Alert
Power supply
<num>, <location>
, failed
A power supply has failed.
The
<num>
is the power supply number.
The
<location>
describes where the failed
power supply is in the chassis.
Alert
System: Module in slot
<slot-num>
encountered PCI config read error: Bus
<PCI-bus-number>
, Dev
<PCI-device-number>
, Reg Offset
<PCI-config-register-offset>
.
The module encountered a hardware
configuration read error.
Alert
System: Module in slot
<slot-num>
encountered PCI config write error: Bus
<PCI-bus-number>
, Dev
<PCI-device-number>
, Reg Offset
<PCI-config-register-offset>
.
The module encountered a hardware
configuration write error.
Alert
System: Module in slot
<slot-num>
encountered PCI memory read error: Mem
Addr
<memory-address>
The module encountered a hardware
memory read error.
The
<memory-address>
is in hexadecimal
format.
Alert
System: Module in slot
<slot-num>
encountered PCI memory write error: Mem
Addr
<memory-address>
.
The module encountered a hardware
memory write error.
The
<memory-address>
is in hexadecimal
format.
Alert
System: Module in slot
<slot-num>
encountered unrecoverable PCI bridge
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) bridge validation failure. The
module will be disabled or powered down.
TABLE 239
Syslog messages (Continued)
Message level
Message
Explanation
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...