PowerConnect B-Series FCX Configuration Guide
355
53-1002266-01
Metro Ring Protocol (MRP)
10
MRP CLI example
The following examples show the CLI commands required to implement the MRP configuration
shown in
Figure 67
on page 348.
NOTE
For simplicity, the figure shows the VLANs on only two switches. The CLI examples implement the
ring on all four switches.
Commands on Switch A (master node)
The following commands configure a VLAN for the ring. The ring VLAN must contain both of the
node interfaces with the ring. Add these interfaces as tagged interfaces, since the interfaces also
must be in each of the customer VLANs configured on the node.
PowerConnect(config)#vlan 2
PowerConnect(config-vlan-2)#tag ethernet 1/1 to 1/2
PowerConnect(config-vlan-2)#metro-ring 1
PowerConnect(config-vlan-2-mrp-1)#name “Metro A”
PowerConnect(config-vlan-2-mrp-1)#master
PowerConnect(config-vlan-2-mrp-1)#ring-interface ethernet 1/1 ethernet 1/2
PowerConnect(config-vlan-2-mrp-1)#enable
PowerConnect(config-vlan-2-mrp-1)#exit
PowerConnect(config-vlan-2)#exit
Active interface
The physical interfaces that are sending and receiving RHPs.
NOTE: If a port is disabled, its state is shown as “disabled”.
NOTE: If an interface is a trunk group, only the primary port of the group
is listed.
Interface Type
Shows if the interface is a regular port or a tunnel port.
RHPs sent
The number of RHPs sent on the interface.
NOTE: This field applies only to the master node. On non-master nodes,
this field contains 0. This is because the RHPs are forwarded in
hardware on the non-master nodes.
RHPs rcvd
The number of RHPs received on the interface.
NOTE: On most Dell PowerConnect devices, this field applies only to the
master node. On non-master nodes, this field contains 0. This is
because the RHPs are forwarded in hardware on the non-master
nodes. However, on the PowerConnect devices, the RHP
received counter on non-master MRP nodes increment. This is
because, on PowerConnect devices, the CPU receives a copy of
the RHPs forwarded in hardware.
TC RHPs rcvd
The number of Topology Change RHPs received on the interface. A
Topology Change RHP indicates that the ring topology has changed.
State changes
The number of MRP interface state changes that have occurred. The
state can be one of the states listed in the Forwarding state field.
Interface Type
Shows if the interface is a regular port or a tunnel port.
TABLE 62
CLI display of MRP ring information (Continued)
This field...
Displays...
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...