792
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Basic IP parameters and defaults – Layer 3 Switches
26
•
Multicast protocols:
-
Internet Group Membership Protocol (IGMP) – refer to
“Changing global IP multicast
parameters”
on page 729
-
Protocol Independent Multicast Dense (PIM-DM) – refer to
“PIM Dense”
on page 733
-
Protocol Independent Multicast Sparse (PIM-SM) – refer to
“PIM Sparse”
on page 742
•
Router redundancy protocols:
-
Virtual Router Redundancy Protocol Extended (VRRPE) – refer to
Chapter 31, “Configuring
VRRP and VRRPE”
-
Virtual Router Redundancy Protocol (VRRP) – refer to
Chapter 31, “Configuring VRRP and
VRRPE”
The following tables list the Layer 3 Switch IP parameters, their default values, and where to find
configuration information.
NOTE
For information about parameters in other protocols based on IP, such as RIP, OSPF, and so on, refer
to the configuration chapters for those protocols.
When parameter changes take effect
Most IP parameters described in this chapter are dynamic. They take effect immediately, as soon
as you enter the CLI command or select the Web Management Interface option. You can verify that
a dynamic change has taken effect by displaying the running-config. To display the running-config,
enter the show running-config or write terminal command at any CLI prompt. (You cannot display
the running-config from the Web Management Interface.)
To save a configuration change permanently so that the change remains in effect following a
system reset or software reload, save the change to the startup-config file:
•
To save configuration changes to the startup-config file, enter the write memory command
from the Privileged EXEC level of any configuration level of the CLI.
•
To save the configuration changes using the Web Management Interface, select the
Save
link
at the bottom of the dialog. Select Yes when prompted to save the configuration change to the
startup-config file on the device flash memory. You also can access the dialog for saving
configuration changes by clicking on Command in the tree view, then clicking on
Save to Flash
.
Changes to memory allocation require you to reload the software after you save the changes to the
startup-config file. When reloading the software is required to complete a configuration change
described in this chapter, the procedure that describes the configuration change includes a step
for reloading the software.
IP global parameters – Layer 3 Switches
Table 144
lists the IP global parameters for Layer 3 Switches.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...