PowerConnect B-Series FCX Configuration Guide
1401
53-1002266-01
Syslog messages
41
Informational
telnet | SSH | web access [by
<username>
]
from src IP <source ip address>, src MAC
<source MAC address>
rejected,
<n>
attempts
There were failed web, SSH, or Telnet login
access attempts from the specified source
IP and MAC address.
•
[by
<user>
<username>
] does not
appear if telnet or SSH clients are
specified.
•
<n>
is the number of times this SNMP
trap occurred in the last five minutes,
or other configured number of
minutes.
Informational
Trunk group (
<ports>
) created by 802.3ad
link-aggregation module.
802.3ad link aggregation is configured on
the device, and the feature has dynamically
created a trunk group (aggregate link).
The
<ports>
is a list of the ports that were
aggregated to make the trunk group.
Informational
user
<username>
added | deleted |
modified from console | telnet | ssh | web |
snmp
A user created, modified, or deleted a local
user account through the Web, SNMP,
console, SSH, or Telnet session.
Informational
vlan
<vlan id>
added | deleted | modified
from console | telnet | ssh | web | snmp
session
A user created, modified, or deleted a VLAN
through the Web, SNMP, console, SSH, or
Telnet session.
Informational
Warm start
The system software (flash code) has been
reloaded.
Informational
Stack: Stack unit
<unit#>
has been deleted
to the stack system
The specified unit has been deleted from
the stacking system.
Informational Stack
unit
<unitNumber>
has been elected
as ACTIVE unit of the stack system
The specified unit in a stack has been
elected as the Master unit for the stacking
system.
Informational Stack:
Stack
unit
<unit#>
has been added to
the stack system
The specified unit has been added to the
stacking system.
Informational
System: Management MAC address changed
to
<mac_address>
The management MAC address of a
stacking system has been changed
Informational System:
Stack
unit
<unit#>
Fan
<fan#>
(
<description>
), failed
The operational status of a fan in the
specified unit in a stack changed from
normal to failure.
Informational System:
Stack
unit
<unit#>
Power supply
<power-supply#>
is down
The operational status of a power supply of
the specified unit in a stack changed from
normal to failure.
Informational System:
Stack
unit
<unit#>
Power supply
<power-supply#>
is up
The operational status of a power supply of
the specified unit in a stack changed from
failure to normal.
Informational System:
Stack
unit
<unit#r>
Fan
<fan#>
(
<description>
), ok
The operational status of a fan in the
specified unit in a stack changed from
failure to normal.
Informational System:
Stack
unit
<unitNumber>
Temperature
<actual-temp>
C degrees,
warning level
<warning-temp>
C degrees,
shutdown level
<shutdown-temp>
C degrees
The actual temperature reading for a unit in
a stack is above the warning temperature
threshold.
TABLE 239
Syslog messages (Continued)
Message level
Message
Explanation
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...