Configuring multi-device port authentication
36
Aging of the Layer 2 hardware entry for a blocked MAC address occurs in two phases, known as
hardware aging and software aging.
On PowerConnect devices, the hardware aging period for blocked MAC addresses is fixed at 70
seconds and is non-configurable. (The hardware aging time for non-blocked MAC addresses is the
length of time specified with the mac-age command.) The software aging period for blocked MAC
addresses is configurable through the CLI, with the mac-authentication max-age command. Once
the hardware aging period ends, the software aging period begins. When the software aging period
ends, the blocked MAC address ages out, and can be authenticated again if the Dell PowerConnect
device receives traffic from the MAC address.
To change the hardware aging period for blocked MAC addresses, enter a command such as the
following.
PowerConnect(config)#mac-authentication hw-deny-age 10
Syntax: [no] mac-authentication hw-deny-age
<num>
The
<num>
parameter is a value from 1 to 65535 seconds. The default is 70 seconds.
Specifying the aging time for blocked MAC addresses
When the Dell PowerConnect device is configured to drop traffic from non-authenticated MAC
addresses, traffic from the blocked MAC addresses is dropped in hardware, without being sent to
the CPU. A Layer 2 CAM entry is created that drops traffic from the blocked MAC address in
hardware. If no traffic is received from the blocked MAC address for a certain amount of time, this
Layer 2 CAM entry is aged out. If traffic is subsequently received from the MAC address, then an
attempt can be made to authenticate the MAC address again.
Aging of the Layer 2 CAM entry for a blocked MAC address occurs in two phases, known as
hardware aging
and
software aging
. The hardware aging period is fixed at 70 seconds and is
non-configurable. The software aging time is configurable through the CLI.
Once the Dell PowerConnect device stops receiving traffic from a blocked MAC address, the
hardware aging begins and lasts for a fixed period of time. After the hardware aging period ends,
the software aging period begins. The software aging period lasts for a configurable amount of
time (by default 120 seconds). After the software aging period ends, the blocked MAC address
ages out, and can be authenticated again if the Dell PowerConnect device receives traffic from the
MAC address.
To change the length of the software aging period for blocked MAC addresses, enter a command
such as the following.
PowerConnect(config)#mac-authentication max-age 180
Syntax: [no] mac-authentication max-age
<seconds>
You can specify from 1 – 65535 seconds. The default is 120 seconds.
Specifying the RADIUS timeout action
A RADIUS timeout occurs when the Dell PowerConnect device does not receive a response from a
RADIUS server within a specified time limit and after a certain number of retries. The time limit and
number of retries can be manually configured using the CLI commands radius-server timeout and
radius-server retransmit, respectively. If the parameters are not manually configured, the Dell
PowerConnect device applies the default value of three seconds with a maximum of three retries.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...