If an untagged port had previously been assigned to a VLAN through dynamic VLAN
assignment, and then another MAC address is authenticated on the same port, but the
RADIUS Access-Accept message for the second MAC address specifies a different VLAN, then it
is considered an authentication failure for the second MAC address, and the configured
authentication failure action is performed. Note that this applies only if the first MAC address
has not yet aged out. If the first MAC address has aged out, then dynamic VLAN assignment
would work as expected for the second MAC address.
•
For dual mode ports, if the RADIUS server returns T:
<vlan-name>
, the traffic will still be
forwarded in the statically assigned PVID. If the RADIUS server returns U:
<vlan-name>
, the
traffic will not be forwarded in the statically assigned PVID.
Configuring the RADIUS server to support dynamic VLAN assignment
To specify VLAN identifiers on the RADIUS server, add the following attributes to the profile for the
MAC address on the RADIUS server, then enable dynamic VLAN assignment on multi-device port
authentication-enabled interfaces.
For information about the attributes, refer to
“Dynamic multiple VLAN assignment for 802.1X ports”
on page 1231.
Also, refer to the example configuration of
“Multi-device port authentication with dynamic VLAN
assignment”
on page 1300.
Specifying to which VLAN a port is moved after its RADIUS-specified VLAN
assignment expires
When a port is dynamically assigned to a VLAN through the authentication of a MAC address, and
the MAC session for that address is deleted on the Dell PowerConnect device, then by default the
port is removed from its RADIUS-assigned VLAN and placed back in the VLAN where it was
originally assigned.
A port can be removed from its RADIUS-assigned VLAN when any of the following occur:
•
The link goes down for the port
•
The MAC session is manually deleted with the mac-authentication clear-mac-session
command
•
The MAC address that caused the port to be dynamically assigned to a VLAN ages out
For example, say port 1/1 is currently in VLAN 100, to which it was assigned when MAC address
0007.eaa1.e90f was authenticated by a RADIUS server. The port was originally configured to be in
VLAN 111. If the MAC session for address 0007.eaa1.e90f is deleted, then port 1/1 is moved from
VLAN 100 back into VLAN 111.
Attribute name
Type
Value
Tunnel-Type
064
13 (decimal) – VLAN
Tunnel-Medium-Type
065
6 (decimal) – 802
Tunnel-Private-Group-ID
081
<vlan-name>
(string)
The
<vlan-name>
value can specify either the name or the number of
one or more VLANs configured on the Dell PowerConnect device.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...