PowerConnect B-Series FCX Configuration Guide
221
53-1002266-01
Configuring standard STP parameters
8
Displaying detailed STP information for a single port in a specific VLAN
Enter a command such as the following to display STP information for an individual port in a
specific VLAN.
Port number and STP state
The internal port number and the port STP state.
The internal port number is one of the following:
•
The port interface number, if the port is the designated port for the LAN.
•
The interface number of the designated port from the received BPDU, if
the interface is not the designated port for the LAN.
The state can be one of the following:
•
BLOCKING – STP has blocked Layer 2 traffic on this port to prevent a
loop. The device or VLAN can reach the root bridge using another port,
whose state is FORWARDING. When a port is in this state, the port does
not transmit or receive user frames, but the port does continue to
receive STP BPDUs.
•
DISABLED – The port is not participating in STP. This can occur when the
port is disconnected or STP is administratively disabled on the port.
•
FORWARDING – STP is allowing the port to send and receive frames.
•
LISTENING – STP is responding to a topology change and this port is
listening for a BPDU from neighboring bridges in order to determine the
new topology. No user frames are transmitted or received during this
state.
•
LEARNING – The port has passed through the LISTENING state and will
change to the BLOCKING or FORWARDING state, depending on the
results of STP reconvergence. The port does not transmit or receive user
frames during this state. However, the device can learn the MAC
addresses of frames that the port receives during this state and make
corresponding entries in the MAC table.
NOTE: If the state is DISABLED, no further STP information is displayed for
the port.
Port Path cost
The STP path cost for the port.
Port Priority
This STP priority for the port. The value is shown as a hexadecimal number.
Root
The ID assigned by STP to the root bridge for this spanning tree.
Designated Bridge
The MAC address of the designated bridge to which this port is connected.
The designated bridge is the device that connects the network segment on
the port to the root bridge.
Designated Port
The port number sent from the designated bridge.
Designated Path Cost
The cost to the root bridge as advertised by the designated bridge that is
connected to this port. If the bridge is the root bridge itself, then the cost is 0.
The identity of the designated bridge is shown in the Designated Bridge field.
Active Timers
The current values for the following timers, if active:
•
Message age – The number of seconds this port has been waiting for a
hello message from the root bridge.
•
Forward delay – The number of seconds that have passed since the last
topology change and consequent reconvergence.
•
Hold time – The number of seconds that have elapsed since
transmission of the last Configuration BPDU.
BPDUs Sent and Received
The number of BPDUs sent and received on this port since the software was
reloaded.
TABLE 51
CLI display of detailed STP information for ports (Continued)
This field...
Displays...
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...