PowerConnect B-Series FCX Configuration Guide
1143
53-1002266-01
Restricting remote access to management functions
32
To allow SSH access to the Dell PowerConnect device to a host with any IP address and MAC
address 0007.e90f.e9a0, enter the following command.
PowerConnect(config)#ip ssh client any 0007.e90f.e9a0
Syntax: [no] ip ssh client any
<mac-addr>
Restricting HTTP and HTTPS connection
You can restrict an HTTP or HTTPS connection to a device based on the client IP address or MAC
address.
To allow HTTP and HTTPS access to the Dell PowerConnect device only to the host with IP address
209.157.22.40
and
MAC address 0007.e90f.ab1c, enter the following command.
PowerConnect(config)#web client 209.157.22.40 0007.e90f.ab1c
Syntax: [no] web client
<ip-addr>
|
<ipv6-addr>
<mac-addr>
The following command allows HTTP and HTTPS access to the Dell PowerConnect device to a host
with any IP address and MAC address 0007.e90f.10ba.
PowerConnect(config)#web client any 0007.e90f.10ba
Syntax: [no] web client any
<mac-addr>
Defining the Telnet idle time
You can define how many minutes a Telnet session can remain idle before it is timed out. An idle
Telnet session is a session that is still sending TCP ACKs in response to keepalive messages from
the device, but is not being used to send data.
To configure the idle time for a Telnet session, use the following command.
PowerConnect(config)#telnet timeout 120
Syntax: [no] telnet timeout
<minutes>
For
<minutes>
enter a value from 0 – 240. The default value is 0 minutes (no timeout).
Changing the login timeout period for Telnet sessions
By default, the login timeout period for a Telnet session is 1 minute. To change the login timeout
period, use the following command.
PowerConnect(config)#telnet login-timeout 5
Syntax: [no] telnet login-timeout
<minutes>
For
<minutes>
, enter a value from 1 to 10. The default timeout period is 1 minute.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...