PowerConnect B-Series FCX Configuration Guide
371
53-1002266-01
Virtual Switch Redundancy Protocol (VSRP)
10
VSRP does not require you to specify an IP address. If you do not specify an address, VSRP
provides Layer 2 redundancy. If you do specify an address, VSRP provides Layer 2 and Layer 3
redundancy.
The Layer 3 redundancy support is the same as VRRPE support. For information, refer to
Chapter
31, “Configuring VRRP and VRRPE”
.
NOTE
The VRID IP address must be in the same subnet as a real IP address configured on the VSRP
interface, but cannot be the same as a real IP address configured on the interface.
NOTE
Failover applies to both Layer 2 and Layer 3.
To specify an IP address to back up, enter a command such as the following at the configuration
level for the VRID.
PowerConnect(config-vlan-200-vrid-1)#ip-address 10.10.10.1
Syntax: [no] ip-address
<ip-addr>
Changing the backup priority
When you enter the backup command to configure the device as a VSRP Backup for the VRID, you
also can change the backup priority and the track priority:
•
The backup priority is used for election of the Master. The VSRP Backup with the highest
priority value for the VRID is elected as the Master for that VRID. The default priority is 100. If
two or more Backups are tied with the highest priority, the Backup with the highest IP address
becomes the Master for the VRID.
•
The track priority is used with the track port feature. Refer to
“VSRP priority calculation”
on
page 360 and
“Changing the default track priority”
on page 374.
To change the backup priority, enter a command such as the following at the configuration level for
the VRID.
PowerConnect(config-vlan-200-vrid-1)#backup priority 75
Syntax: [no] backup [priority
<value>
] [track-priority
<value>
]
The priority
<value>
parameter specifies the backup priority for this interface and VRID. Specify a
value as follows:
•
For VRRP, specify a value from 3 – 254. The default is 100.
•
For VSRP and VRRP-E, specify a value from 6 – 255. The default is 100.
For a description of the track-priority
<value>
parameter, refer to
“Changing the default track
priority”
on page 374.
Saving the timer values received from the master
The Hello messages sent by a VRID master contain the VRID values for the following VSRP timers:
•
Hello interval
•
Dead interval
•
Backup Hello interval
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...