PowerConnect B-Series FCX Configuration Guide
367
53-1002266-01
Virtual Switch Redundancy Protocol (VSRP)
10
Configuring basic VSRP parameters
To configure VSRP, perform the following required tasks:
•
Configure a port-based VLAN containing the ports for which you want to provide VSRP service.
NOTE
If you already have a port-based VLAN but only want to use VSRP on a sub-set of the VLANs
ports, you can selectively remove ports from VSRP service in the VLAN. Refer to
“Removing a
port from the VRID VLAN”
on page 370.
•
Configure a VRID:
•
Specify that the device is a backup. Since VSRP, like VRRPE, does not have an “owner”, all
VSRP devices are backups. The active device for a VRID is elected based on the VRID
priority, which is configurable.
•
Activate the VRID.
The following example shows a simple VSRP configuration.
PowerConnect(config)#vlan 200
PowerConnect(config-vlan-200)#tag ethernet 1/1 to 1/8
PowerConnect(config-vlan-200)#vsrp vrid 1
PowerConnect(config-vlan-200-vrid-1)#backup
PowerConnect(config-vlan-200-vrid-1)#activate
Syntax: [no] vsrp vrid
<num>
The
<num>
parameter specifies the VRID and can be from 1 – 255.
Syntax: [no] backup [priority
<value>
] [track-priority
<value>
]
This command is required. In VSRP, all devices on which a VRID are configured are Backups. The
Master is then elected based on the VSRP priority of each device. There is no “owner” device as
there is in VRRP.
For information about the command optional parameters, refer to the following:
•
“Changing the backup priority”
on page 371
•
“Changing the default track priority”
on page 374
Syntax: [no] activate
or
RIP parameters
Suppression of
RIP
advertisements
A Layer 3 Switch that is running RIP normally
advertises routes to a backed up VRID even when the
Layer 3 Switch is not currently the active Layer 3
Switch for the VRID. Suppression of these
advertisements helps ensure that other Layer 3
Switches do not receive invalid route paths for the
VRID.
NOTE: This parameter is valid only on Layer 3
Switches.
Disabled
(routes are advertised)
page 375
TABLE 63
VSRP parameters (Continued)
Parameter
Description
Default
See page...
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...