838
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring IP parameters – Layer 3 Switches
26
Syntax: [no] ip forward-protocol udp
<udp-port-name>
|
<udp-port-num>
The
<udp-port-name>
parameter can have one of the following values. For reference, the
corresponding port numbers from RFC 1340 are shown in parentheses. If you specify an
application name, enter the name only, not the parentheses or the port number shown here:
•
bootpc (port 68)
•
bootps (port 67)
•
discard (port 9)
•
dns (port 53)
•
dnsix (port 90)
•
echo (port 7)
•
mobile-ip (port 434)
•
netbios-dgm (port 138)
•
netbios-ns (port 137)
•
ntp (port 123)
•
tacacs (port 65)
•
talk (port 517)
•
time (port 37)
•
tftp (port 69)
In addition, you can specify any UDP application by using the application UDP port number.
The
<udp-port-num>
parameter specifies the UDP application port number. If the application you
want to enable is not listed above, enter the application port number. You also can list the port
number for any of the applications listed above.
To disable forwarding for an application, enter a command such as the following.
PowerConnect(config)# no ip forward-protocol udp snmp
This command disables forwarding of SNMP requests to the helper addresses configured on Layer
3 Switch interfaces.
Configuring an IP helper address
To forward a client broadcast request for a UDP application when the client and server are on
different networks, you must configure a helper address on the interface connected to the client.
Specify the server IP address or the subnet directed broadcast address of the IP subnet the server
is in as the helper address.
You can configure up to 16 helper addresses on each interface. You can configure a helper
address on an Ethernet port or a virtual interface.
To configure a helper address on interface 2 on chassis module 1, enter the following commands.
PowerConnect(config)# interface ethernet 1/2
PowerConnect(config-if-1/2)# ip helper-address 1 207.95.7.6
The commands in this example change the CLI to the configuration level for port 1/2, then add a
helper address for server 207.95.7.6 to the port. If the port receives a client request for any of the
applications that the Layer 3 Switch is enabled to forward, the Layer 3 Switch forwards the client
request to the server.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...