PowerConnect B-Series FCX Configuration Guide
1339
53-1002266-01
Chapter
38
Protecting Against Denial of Service Attacks
Table 232
lists individual Dell PowerConnect switches and the DoS protection features they
support.
This chapter explains how to protect your Dell PowerConnect devices from Denial of Service (DoS)
attacks.
In a Denial of Service (DoS) attack, a router is flooded with useless packets, hindering normal
operation. Dell PowerConnect devices include measures for defending against two types of DoS
attacks Smurf attacks and TCP SYN attacks.
Protecting against Smurf attacks
A
Smurf attack
is a kind of DoS attack in which an attacker causes a victim to be flooded with
Internet Control Message Protocol (ICMP) echo (Ping) replies sent from another network.
Figure 174
illustrates how a Smurf attack works.
FIGURE 174
How a Smurf attack floods a victim with ICMP replies
The attacker sends an ICMP echo request packet to the broadcast address of an intermediary
network. The ICMP echo request packet contains the spoofed address of a victim network as its
source. When the ICMP echo request reaches the intermediary network, it is converted to a Layer 2
broadcast and sent to the hosts on the intermediary network. The hosts on the intermediary
network then send ICMP replies to the victim network.
TABLE 232
Supported DoS protection features
Feature
PowerConnect B-Series FCX
Smurf attack (ICMP attack) protection
Yes
TCP SYN attack protection
Yes
2
1
3
Attacker
Intermediary
Victim
Att
a
cker
s
end
s
ICMP echo req
u
e
s
t
s
to
bro
a
dc
as
t
a
ddre
ss
on Intermedi
a
ry’
s
network,
s
poofing Victim’
s
IP
a
ddre
ss
as
the
s
o
u
rce
If Intermedi
a
ry h
as
directed bro
a
dc
as
t
forw
a
rding en
a
bled, ICPM echo req
u
e
s
t
s
a
re bro
a
dc
as
t to ho
s
t
s
on Intermedi
a
ry’
s
network
The ho
s
t
s
on Intermedi
a
ry’
s
network
s
end replie
s
to Victim, in
u
nd
a
ting Victim
with ICPM p
a
cket
s
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...