452
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring IP subnet, IPX network and protocol-based VLANs
13
To configure a specific path-cost or priority value for a given port, enter those values using the key
words in the brackets [ ] shown in the syntax summary below. If you do not want to specify values
for any given port, this portion of the command is not required.
Syntax: vlan
<vlan-id>
by port
Syntax: [no] spanning-tree
Syntax: spanning-tree [ethernet [
<slotnum>
/]
<portnum>
path-cost
<value>
priority
<value>
]
forward-delay
<value>
hello-time
<value>
maximum-age
<time>
priority
<value>
Bridge STP parameters (applied to all ports within a VLAN):
•
Forward Delay – the period of time a bridge will wait (the listen and learn period) before
forwarding data packets. Possible values: 4 – 30 seconds. Default is 15.
•
Maximum Age – the interval a bridge will wait for receipt of a hello packet before initiating a
topology change. Possible values: 6 – 40 seconds. Default is 20.
•
Hello Time – the interval of time between each configuration BPDU sent by the root bridge.
Possible values: 1 – 10 seconds. Default is 2.
•
Priority – a parameter used to identify the root bridge in a network. The bridge with the lowest
value has the highest priority and is the root. Possible values: 1 – 65,535. Default is 32,678.
Port parameters (applied to a specified port within a VLAN):
•
Path Cost – a parameter used to assign a higher or lower path cost to a port. Possible values: 1
– 65535. Default is (1000/Port Speed) for Half-Duplex ports and is (1000/Port Speed)/2 for
Full-Duplex ports.
•
Priority – value determines when a port will be rerouted in relation to other ports. Possible
values: 0 – 255. Default is 128.
Configuring IP subnet, IPX network and
protocol-based VLANs
Protocol-based VLANs provide the ability to define separate broadcast domains for several unique
Layer 3 protocols within a single Layer 2 broadcast domain. Some applications for this feature
might include security between departments with unique protocol requirements. This feature
enables you to limit the amount of broadcast traffic end-stations, servers, and routers need to
accept.
Configuration example
Suppose you want to create five separate Layer 3 broadcast domains within a single Layer 2 STP
broadcast domain:
•
Three broadcast domains, one for each of three separate IP subnets
•
One for IPX Network 1
•
One for the Appletalk protocol
Also suppose you want a single router interface to be present within all of these separate broadcast
domains, without using IEEE 802.1Q VLAN tagging or any proprietary form of VLAN tagging.
Figure 96
shows this configuration.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...