TABLE 41
Cable statistics
This line...
Displays...
Port
The port that was tested.
Speed
The port current line speed.
Local pair
The local link name. Refer to
Table 40
.
Pair Length
The cable length when terminated, or the distance to the point of fault
when the line is not up.
Remote pair
The remote link name.
Pair status
The status of the link. This field displays one of the following:
•
Terminated: The link is up.
•
Shorted: A short is detected in the cable.
•
Open: An opening is detected in the cable.
•
ImpedMis: The impedance is mismatched.
•
Failed: The TDR test failed.
TABLE 42
Supported fiber optic transceivers
Label
Manufacturing part number
Type
Dell part number
Supports Digital
Optical Monitoring?
E1MG-BXD
TRPBG1LXDBVS2FY 1000Base-BXD
PYD7H
No
E1MG-BXU
TRPBG1LXDBBSHFY
1000Base-BXU Y0WGM
No
E1MG-LHA-OM
WST-S5CCIU-502FD
1000Base-LHA 3TP6Y
Yes
E1MG-LX-OM
FTLF1318P2BTL-F1
AFCT-5715PZ-FD
1000Base-LX 6JCR4
Yes
E1MG-100FX-OM
FTLF1217P2BTL-F1
100Base-FX JCGF5
Yes
E1MG-100FX-IR-OM
FTLF1323P1BTR-FD
100Base-FX-IR, 15 km
X5FD3
Yes
E1MG-SX-OM
FTLF8519P2BNL-F1
AFBR-5715PZ-FD
1000Base-SX XR0H5
Yes
10G-XFP-ER FTRX-1611-3-F1
FIM31110/210
FIM3112/230
10GBase-ER XFP, 40 km
V0396
Yes
10G-XFP-LR
FTLX1412D3BCL-F1
AFCT 721XPDZ-FD1
JXPR01LG081FY
10GBase-LR XFP, 10 km
98CPC
Yes
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...