If the software has been running less than 15 minutes (the maximum interval for utilization
statistics), the command indicates how long the software has been running. An example is given
below.
To display utilization statistics for a specific number of seconds, enter a command such as the
following.
When you specify how many seconds’ worth of statistics you want to display, the software selects
the sample that most closely matches the number of seconds you specified. In this example,
statistics are requested for the previous two seconds. The closest sample available is actually for
the previous 1 second plus 80 milliseconds.
Syntax: show process cpu [
<num>
]
The
<num>
parameter specifies the number of seconds and can be from 1 – 900. If you use this
parameter, the command lists the usage statistics only for the specified number of seconds. If you
do not use this parameter, the command lists the usage statistics for the previous one-second,
one-minute, five-minute, and fifteen-minute intervals.
PowerConnect#show process cpu
Process Name
5Sec(%)
1Min(%)
5Min(%)
15Min(%)
Runtime(ms)
ARP
0.01
0.03
0.09
0.22
9
BGP
0.00
0.00
0.00
0.00
0
GVRP
0.00
0.03
0.04
0.07
4
ICMP
0.00
0.00
0.00
0.00
0
IP
0.00
0.00
0.00
0.00
0
OSPF
0.00
0.00
0.00
0.00
0
RIP
0.00
0.00
0.00
0.00
0
STP
0.00
0.00
0.00
0.00
0
VRRP
0.00
0.00
0.00
0.00
0
PowerConnect#show process cpu
The system has only been up for 6 seconds.
Process Name
5Sec(%)
1Min(%)
5Min(%)
15Min(%)
Runtime(ms)
ARP
0.01
0.00
0.00
0.00
0
BGP
0.00
0.00
0.00
0.00
0
GVRP
0.00
0.00
0.00
0.00
0
ICMP
0.01
0.00
0.00
0.00
1
IP
0.00
0.00
0.00
0.00
0
OSPF
0.00
0.00
0.00
0.00
0
RIP
0.00
0.00
0.00
0.00
0
STP
0.00
0.00
0.00
0.00
0
VRRP
0.00
0.00
0.00
0.00
0
PowerConnect#show process cpu 2
Statistics for last 1 sec and 80 ms
Process Name
Sec(%)
Time(ms)
ARP
0.00
0
BGP
0.00
0
GVRP
0.01
1
ICMP
0.00
0
IP
0.00
0
OSPF
0.00
0
RIP
0.00
0
STP
0.01
1
VRRP
0.00
0
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...