Displaying IP configuration information and statistics
26
The show ip traffic command displays the following information.
TABLE 168
CLI display of IP traffic statistics – Layer 2 Switch
This field...
Displays...
IP statistics
received
The total number of IP packets received by the device.
sent
The total number of IP packets originated and sent by the device.
fragmented
The total number of IP packets fragmented by this device to accommodate the MTU of this
device or of another device.
reassembled
The total number of fragmented IP packets that this device re-assembled.
bad header
The number of IP packets dropped by the device due to a bad packet header.
no route
The number of packets dropped by the device because there was no route.
unknown proto
The number of packets dropped by the device because the value in the Protocol field of the
packet header is unrecognized by this device.
no buffer
This information is used by Dell customer support.
other errors
The number of packets that this device dropped due to error types other than the types listed
above.
ICMP statistics
The ICMP statistics are derived from RFC 792, “Internet Control Message Protocol”, RFC 950, “Internet Standard
Subnetting Procedure”, and RFC 1256, “ICMP Router Discovery Messages”. Statistics are organized into Sent and
Received. The field descriptions below apply to each.
total
The total number of ICMP messages sent or received by the device.
errors
This information is used by Dell customer support.
unreachable
The number of Destination Unreachable messages sent or received by the device.
time exceed
The number of Time Exceeded messages sent or received by the device.
parameter
The number of Parameter Problem messages sent or received by the device.
source quench
The number of Source Quench messages sent or received by the device.
redirect
The number of Redirect messages sent or received by the device.
echo
The number of Echo messages sent or received by the device.
echo reply
The number of Echo Reply messages sent or received by the device.
timestamp
The number of Timestamp messages sent or received by the device.
timestamp reply
The number of Timestamp Reply messages sent or received by the device.
addr mask
The number of Address Mask Request messages sent or received by the device.
addr mask reply
The number of Address Mask Replies messages sent or received by the device.
irdp advertisement The number of ICMP Router Discovery Protocol (IRDP) Advertisement messages sent or
received by the device.
irdp solicitation
The number of IRDP Solicitation messages sent or received by the device.
UDP statistics
received
The number of UDP packets received by the device.
sent
The number of UDP packets sent by the device.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...