PowerConnect B-Series FCX Configuration Guide
1295
53-1002266-01
Displaying multi-device port authentication information
36
Displaying multi-device port authentication information
for a port
To display a summary of Multi-Device Port Authentication for ports on a device, enter the following
command
Syntax: show auth-mac-address ethernet
<port>
Table 229
explains the information in the output.
Displaying multi-device port authentication settings
and authenticated MAC addresses
To display the multi-device port authentication settings and authenticated MAC addresses for a
port where the feature is enabled, enter the following command.
Syntax: show auth-mac-address [detail] [ethernet
<port>
]
Specify the
<port>
variable in the following formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
TABLE 229
Output of show auth-mac-address
This field...
Displays...
MAC Address
The MAC addresses learned on the port. If the packet for which multi-device port
authentication was performed also contained an IP address, the IP address is also
displayed.
Port
ID of the port on which the MAC address was learned.
VLAN
VLAN of which the port is a member.
Authenticated
Whether the MAC address has been authenticated by the RADIUS server.
Time
The time the MAC address was authenticated. If the clock is set on the Dell PowerConnect
device, then the actual date and time are displayed. If the clock has not been set, the time is
displayed relative to when the device was last restarted.
Age
The age of the MAC address entry in the authenticated MAC address list.
Dot1x
Indicates if 802.1X authentication is enabled or disabled for the MAC address
PowerConnect#show auth-mac-addresses ethernet 18/1
-------------------------------------------------------------------------------
MAC Address Port Vlan Authenticated Time Age Dot1x
-------------------------------------------------------------------------------
000f.ed00.0001 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.012d 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.0321 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.0259 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.0065 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.0385 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.0191 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.02bd 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.00c9 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.01f5 18/1 87 Yes 00d01h03m17s Ena Ena
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...