Optional configuration tasks
30
For each keyword,
<num>
indicates the number of seconds. The Keep Alive Time can be 0 through
65535. The Hold Time can be 0 or 3 through 65535 (1 and 2 are not allowed). If you set the Hold
Time to 0, the router waits indefinitely for messages from a neighbor without concluding that the
neighbor is dead.
Changing the BGP4 next-hop update timer
By default, the Layer 3 Switch updates its BGP4 next-hop tables and affected BGP4 routes five
seconds after IGP route changes. You can change the update timer to a value from 1 through 30
seconds.
To change the BGP4 update timer value, enter a command such as the following at the BGP
configuration level of the CLI.
PowerConnect(config-bgp-router)#update-time 15
This command changes the update timer to 15 seconds.
Syntax: [no] update-time
<secs>
The
<secs>
parameter specifies the number of seconds and can be from 1 through 30. The default
is 5.
Enabling fast external fallover
BGP4 routers rely on KEEPALIVE and UPDATE messages from neighbors to signify that the
neighbors are alive. For BGP4 neighbors that are two or more hops away, such messages are the
only indication that the BGP4 protocol has concerning the alive state of the neighbors. As a result,
if a neighbor dies, the router will wait until the Hold Time expires before concluding that the
neighbor is dead and closing its BGP4 session and TCP connection with the neighbor.
The router waits for the Hold Time to expire before ending the connection to a directly-attached
BGP4 neighbor that dies.
For directly attached neighbors, the router immediately senses loss of a connection to the neighbor
from a change of state of the port or interface that connects the router to its neighbor. For directly
attached EBGP neighbors, the router can use this information to immediately close the BGP4
session and TCP connection to locally attached neighbors that die.
NOTE
The fast external fallover feature applies only to directly attached EBGP neighbors. The feature does
not apply to IBGP neighbors.
If you want to enable the router to immediately close the BGP4 session and TCP connection to
locally attached neighbors that die, use either of the following methods.
To enable fast external fallover, enter the following command.
PowerConnect(config-bgp-router)#fast-external-fallover
To disable fast external fallover again, enter the following command.
PowerConnect(config-bgp-router)#no fast-external-fallover
Syntax: [no] fast-external-fallover
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...