1256
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Displaying 802.1X information
34
The output of the show dot1x config command for an interface displays the configured port control
for the interface. This command also displays information related to 802.1X multiple
host-authentication.
The following is an example of the output of the show dot1x config command for an interface.
Syntax: show dot1x config ethernet
<port>
Specify the
<port>
variable in the following formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
The following table lists the fields in the display.
Displaying information about the dot1x MAC sessions on each port
The show dot1x mac-session command displays information about the dot1x-mac-sessions on
each port on the device. The output also shows the authenticator PAE state.
TABLE 216
Output from the show dot1x config command
This field...
Displays...
Port-Control
The configured port control type for the interface. This can be one of the following:
force-authorized – The controlled port is placed unconditionally in the authorized
state, allowing all traffic. This is the default state for ports on the Dell PowerConnect
device.
force-unauthorized – The controlled port is placed unconditionally in the
unauthorized state. No authentication takes place for any connected 802.1X Clients.
auto – The authentication status for each 802.1X Client depends on the
authentication status returned from the RADIUS server.
filter strict security
Whether strict security mode is enabled or disabled on the interface.
PVID State
The port default VLAN ID (PVID) and the state of the port PVID. The PVID state can be
one of the following
Normal – The port PVID is not set by a RADIUS server, nor is it the restricted VLAN.
RADIUS – The port PVID was dynamically assigned by a RADIUS server.
RESTRICTED – The port PVID is the restricted VLAN.
Original PVID
The originally configured (not dynamically assigned) PVID for the port.
PVID mac total
The number of devices transmitting untagged traffic on the port PVID.
PVID mac authorized
The number of devices transmitting untagged traffic on the port PVID as a result of
dynamic VLAN assignment.
num mac sessions
The number of dot1x-mac-sessions on the port.
num mac authorized
The number of authorized dot1x-mac-sessions on the port.
PowerConnect#show dot1x config e 3/1
Port-Control : control-auto
filter strict security : Enable
PVID State : Restricted (10)
Original PVID : 10
PVID mac total : 1
PVID mac authorized : 0
num mac sessions : 1
num mac authorized : 0
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...