background image

 
 
 

Leonton

 

ET2-0602-M Series 

(ET2-0602-M / ET2-0602-M-T)

 

 

 

 

 

 

User Manual

 

Version 1.0

 

Содержание ET2-0602-M Series

Страница 1: ...Leonton ET2 0602 M Series ET2 0602 M ET2 0602 M T User Manual Version 1 0...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...are Description 3 Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Cabling 6 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 8 Mounting Installation 9 DIN Rail Mounting 9 Wall...

Страница 5: ...perating temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key...

Страница 6: ...ion If the DC voltage is supplied by an external circuit please use a protection device on the power supply input Supply by UL Listed industrial use power The industrial Ethernet switch s hardware spe...

Страница 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of ET2 0602 M series W x H x D is 30mm x 142mm x 99mm Figure 2 1 ET2 0602 M Series Physical Dimensions...

Страница 8: ...s shown below in Figure 2 2 Figure 2 2 The Front Panel of ET2 0602 M Series Top View Figure 2 3 below shows the top panel of the ET2 0602 M series switches that is equipped with one 6 pin removal term...

Страница 9: ...tive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional LAN Port LINK ACT SPEED Green On Connecte...

Страница 10: ...n t stare into the Laser LED Beam Cabling Use the two four twisted pair category 5e or the above cabling for RJ 45 port connections The cable between the switch and the link partner switch hub worksta...

Страница 11: ...screws to prevent the wires from loosening as shown below in Figure 2 10 Figure 2 10 Power Terminal Block Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block...

Страница 12: ...luding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 11 Figure 2 11 W...

Страница 13: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Страница 14: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Страница 15: ...ottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket...

Страница 16: ...the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power I...

Страница 17: ...ssist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicatio...