6
Fiber Port
The fiber port of SC type connector can work in multi-mode or single-mode. When connecting the fiber
port to another one, please follow the figure below to connect accordingly. Wrong connection will cause
the port works abnormally.
Figure 2. 1: SC Connector
Caution
This is a Class 1 Laser/LED product.
Don’t stare into the Laser/LED Beam.
Cabling
Use the two/four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The
cable between the switch and the link partner (switch, hub, workstation, etc.) must be less than
100 meters (328 ft.) long.
Wiring the Power Inputs
Please follow the below steps to insert the power wire.
Step 1.
Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.9.
Figure 2.9: Power Terminal Block