1294
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Displaying multi-device port authentication information
36
Displaying the authenticated MAC addresses
To display the MAC addresses that have been successfully authenticated, enter the show
auth-mac-addresses authorized-mac command.
Syntax: show auth-mac-addresses authorized-mac
Displaying the non-authenticated MAC addresses
To display the MAC addresses for which authentication was not successful, enter the following
command
Syntax: show auth-mac-addresses unauthorized-mac
Table 229
explains the information in the output.
Time
The time at which the MAC address was authenticated. If the clock is set on the Dell
PowerConnect device, then the actual date and time are displayed. If the clock has not
been set, then the time is displayed relative to when the device was last restarted.
Age
The age of the MAC address entry in the authenticated MAC address list.
CAM Index
If the MAC address is blocked, this is the index entry for the Layer 2 CAM entry created
for this MAC address. If the MAC address is not blocked, either through successful
authentication or through being placed in the restricted VLAN, then “N/A” is displayed.
If the hardware aging period has expired, then “ffff” is displayed for the MAC address
during the software aging period.
TABLE 228
Output from the show authenticated-mac-address
<address>
command (Continued)
This field...
Displays...
PowerConnect#show auth-mac-addresses authorized-mac
-------------------------------------------------------------------------------
MAC Address Port Vlan Authenticated Time Age dot1x
-------------------------------------------------------------------------------
0030.4874.3181 15/23 101 Yes 00d01h03m17s Ena Ena
000f.ed00.0001 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.012d 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.0065 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.0191 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.01f5 18/1 87 Yes 00d01h03m17s Ena Ena
PowerConnect#show auth-mac-addresses unauthorized-mac
-------------------------------------------------------------------------------
MAC Address Port Vlan Authenticated Time Age dot1x
-------------------------------------------------------------------------------
000f.ed00.0321 18/1 87 No 00d01h03m17s H44 Ena
000f.ed00.0259 18/1 87 No 00d01h03m17s H44 Ena
000f.ed00.0385 18/1 87 No 00d01h03m17s H44 Ena
000f.ed00.02bd 18/1 87 No 00d01h03m17s H44 Ena
000f.ed00.00c9 18/1 87 No 00d01h03m17s H44 Ena
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...