152
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Troubleshooting an IronStack
5
Troubleshooting an unsuccessful stack build
If you are unable to build a stack, (for example, the show stack command does not display any
stack units), perform the following steps.
1. Enter the show run command on each unit to make sure the configuration contains “stack
enable”. If it does not, enter the stack enable command on the unit. Before a stack is formed,
you can still access the console port on each device. Once a stack is successfully formed, you
are redirected to the Active Controller.
NOTE
If you are building a stack using secure-setup, you do not have to enter stack enable on each
unit.
2. Check that all of your stacking port connections are secure and working properly. Enter the
show interface stack on each device to confirm that the stacking port links are up and the
ports are in the forward state.
PowerConnect# show interfaces stack
Port Link State Dupl Speed Trunk Tag P MAC Name
1/2/1 Up Forward Full 10G None No 1 0012.f2eb.a902
1/2/2 Up Forward Full 10G None No 1 0012.f2eb.a904
3. Confirm that all of the devices are running the same software image
4. Use the show log command to display any IPC version mismatch messages. These messages
appear in one minute when receiving mismatched probe packets, and then once every 10
minutes.
5. Type show stack ipc to see if any traffic has been sent or received. Enter clear stack ipc to clear
the traffic statistics and then enter show stack ipc again so you can easily see differences in
traffic flow.
PowerConnect# show stack ipc
Recv IPC 330 packets
Message types have callbacks:
1 : Reliable IPC message 2 : Reliable IPC atomic batch
.... more message types removed.
Send message types:
[5]=190, [6]=10, [9]=636, [11]=2,
[14]=126,
Recv message types:
[5]=224, [6]=6, [14]=90, [18]=2,
[20]=1, [27]=9,
Statistics:
send pkt num : 964, recv pkt num : 330,
send msg num : 964, recv msg num : 330,
send frag pkt num : 0, recv frag pkt num : 0,
pkt buf alloc : 964,
Reliable-mail send success receive time us
target ID 0 0 0 0
target MAC 0 0 2 0
There is 0 current jumbo IPC session
Possible errors:
*** state not ready : 1,
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...