                                         Non Contact Magnetic Safety Switches  

 

 

IMPORTANT NOTE: 
Read and understand these instructions before installing, operating, or maintaining this equipment. 

The product is designed to be a component of a customized safety oriented control system. It is the responsibility of the user to ensure the correct overall functionality of its systems and machines. 
IDEM, its subsidiaries and affiliates, are not in a position to guarantee all of the characteristics of a given system or product not designed by IDEM. 
 

APPLICATION:

  

Coded Non Contact switches are designed to interlock hinged, sliding or removable guard doors. They are specifically advantageous when: 

a)

 

poor guard alignment exists                                                                                                                                                                                                                                                                                                        

b)

 

high hygiene requirements exist  e.g. food industry hose down                                                                                                                                                                               

c)

 

a long mechanical life is required (no moving or touching parts). 

When used in combination with a Dual Channel Safety Relay or Control Device, Magnetic Non-Contact Switches can be used to provide protection up to Category 4 and PLe to ISO13849-1. 
 

OPERATION:

  

All Magnetic Non-Contact Safety Switches are designed to conform to EN60947-5-3 and be used as directed by ISO14119 and EN ISO12100. They have magnetic sensing which provides a wide 
sensing distance and provides a high tolerance to misalignment after sensing. They can operate in extreme environments of temperature and moisture.

  

 
IMPORTANT: 

The Risk Assessment for the particular application should include the risk of spare actuators. Spare actuators should not be readily available and must be securely controlled. 
The safety functions and mechanics must be tested regularly. For applications were infrequent guard access is foreseeable, the system must have a manual function test to detect a possible 
accumulation of faults. At least once per month for PLe Cat3/4 or once per year for PLd Cat3 (ISO13849-1).  Where possible it is recommended that the control system of the machine demands and 
monitors these tests, and stops or prevents the machine from starting if the test is not done. (See ISO14119). 
 

INSTALLATION: 

Installation of all Non Contact Switches must be in accordance with a risk assessment for the individual application. 
Installation of the devices must be carried out by a competent person with appropriate experience of machine control integration 

 

The use of a Safety Relay or Control Device is recommended for monitoring magnetic switches. These devices monitor 2 redundant circuits as per ISO13849-1 for up to PLe /Category 4 protection.  
M4 mounting bolts must be used to fix the switches. (Except RPR / RMR types, these types require fitting through 30.5mm clearance holes. The lock nuts supplied must be used to secure the 
switches). Tightening torque for mounting bolts to ensure reliable fixing is 1.0 Nm.  Always mount on to Non Ferrous materials. The recommended setting gap is 5mm. The Safety switch must not be 
used as a mechanical stop or be adjusted by striking with a hammer. The actuator must not be allowed to strike the switch. Do not mount adjacent switches or actuators closer than 30mm.                      
Typical misalignment tolerance after setting is 5mm. 
 

IMPORTANT: The NC switch contacts are potential free and are internally fused. To protect the internal fuse, all switches must be externally fused at a lower rating (see Technical data). 

After installation always check each switch function by opening and closing each guard individually in turn and ensuring that the LED’s on the Safety Relay or Control Device are illuminated when the 
switch is closed and are extinguished when the switch is open. Check that the machine stops and cannot be re-started when each switch is open.                                                           
For MPR types, fit the protective screw covers after the final checks have been completed. 
 

ACTUATOR OPERATING DIRECTIONS FOR OPTIMUM PERFORMANCE: 

                                                                                                            Operating Instructions         

   

 

   

   

     

 

                                                                     

 

 

 
 
 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 

MAINTENANCE: 

Monthly: Check alignment of actuator and look for signs of mechanical damage to the switch casing. Check wiring for signs of damage.  
Check each switch function by opening and closing each guard individually in turn and ensuring that the appropriate LED’s on the Safety Relay are illuminated when the switch is closed and are 
extinguished when the switch is open. Check that the machine stops and cannot be re-started when each switch is open. 
Never repair any switch, actuator or integral cables. Replace any switch displaying signs of mechanical damage to the casing or cables. 

These requirements form part of the product warranty.

 

 

 
 
 

                                          

 

 
 
 
 

 

 

               MPR  MMR-H                       SPR  SMR   SMR-F                                       WPR  WMR                                     LPR  LMR                                         CPR  CMR   CMR-F       

 

 

 

 

 

 

 

 

RPR  RMR      

 

 

 

 

SPR       (PLASTIC) 
SMR       (S/STEEL) 
SMR-F   (S/STEEL) 
SMR-H   (S/STEEL) 

WPR   (PLASTIC) 
WMR   (S/STEEL) 

 
MPR      (PLASTIC) 
MMR-H  (S/STEEL) 

LPR   (PLASTIC) 
LMR   (S/STEEL) 

CPR   (PLASTIC) 
CMR   (S/STEEL) 
CMR-F (S/STEEL) 

RPR   (PLASTIC) 
RMR   (S/STEEL) 

   

WARNING:  DO NOT DEFEAT, TAMPER, OR BYPASS THE SAFETY FUNCTION.   

                                        FAILURE TO DO SO CAN RESULT IN DEATH OR SERIOUS INJURY.  
 
         AVERTISSMENT: NE PAS DESACTIVER, MODIFIER, RETIRER, OU CONTOURNER  
                                       CETI INTERVERROUILLAGE IL PEUT EN RESULTER DES   
                                       BLESSURES GRAVES DU PERSONNEL UTILISATEUR.   
 

 
 

Original Instructions. 

 
To request this data sheet in other languages please contact 

[email protected]

 

Um dieses Datenblatt in Deutscher Sprache wenden Sie sich bitte anfordern 

[email protected]

 

Pour obtenir cette fiche en Français, veuillez contacter 

[email protected]

 

Para solicitar esta hoja de datos en Español, por favor contacto con 

[email protected]

 

 

Отзывы: