background image

B-1715(3)

INSTRUCTION SHEET - HS5L Series 

Solenoid Type Safety Switch

( 1 / 8 )

2016.04

2

Specifications and Ratings

*2  Ratings approved by safety agencies
 

(1)TÜV/CCC rating  AC-15 250V/0.75A

 

 

DC-13 30V/2.3A

 

(2)UL , c-UL rating  AC-15 250V/0.75A : Pilot Duty

 

 

DC-13 30V/1A : Pilot Duty

The M20 threaded opening must be filled by a Listed or 

Recognized Component Liquid-Tight Flexible Cord Fitting 

in order to maintain the Tye 4X Indoor use only rating.

 

(3)KOSHA rating 

AC-15 250V/0.75A

 

 

DC-13 30V/1A 

*3  Basic insulation of 2.5kV impuise withstand circuits and between contact circuit 

SELV(safety extra low voltage) or circuits (such as 230V AC circuits) at the same 

time, the SELV or PELV arequirements are met any more.

*4  The actuator locking strength is rated at 1400N of static load. Do not apply a load 

higher than the rated value. When a higher load is expected to work on the 

actuator, provide an additional system consisting of another safety switch without 

lock (such as the HS5D safety switch) or a sensor to detect door opening and stop 

the machine.

*5  F1max is maximum force. The actuator’s guard-locking force Fzh is calculated in 

accodance with GS-ET-19:

*6 Make sure that a fast acting fuse for short-circuit protection trips before 

overhea ing of  he wires.  

1

Type

HS5L-VD44LM-G

Solenoid Voltage / Lock Mechanism

 

4 : 24V DC / Spring Lock

  7Y : 24V DC / Solenoid Lock
Pilot Light Rated Voltage

 

4 : 24V DC

Indicator Color 

 

G : Green

Circuit Code

Rear Unlock Button

 Blank : Wi hout Rear Unlock Button 

 

L : Rear Unlock Button

     

Standard type

Contact Congifiguration

*1  Only type No. on √ mark are supplied as standard.

 

Contact IDEC for the other if required.

Spring Lock Type Solenoid Lock Type

Main

circuit

-

-

-

-

-

-

-

-

-

-

-

1NC+1NC

1NC+1NC

-

-

1NC+1NC

1NC+1NC

1NC+1NC

1NC+1NC

1NC+1NC

1NC+1NC

1NC+1NC

-

-

-

-

-

-

-

HS5L-

7Y4M-G

-
-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

HS5L-

44LM-G

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

HS5L-

44M-G

-

-


-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Door monitor

circuit 

1NC

2NC

1NC,1NO

-

1NC,1NO

1NC,1NO

2NC

2NC

3NC

2NC,1NO

1NC

-

1NO

-

1NO

1NO

1NC

1NC

2NC

1NC,1NO

-

1NO

1NO

1NC

1NC

2NC

1NC,1NO

-

Lock monitor

circuit 

1NC

-

-

2NC

1NC,1NO

2NC

1NC,1NO

2NC

1NC

1NC

2NC,1NO

-

1NC

1NC,1NO

1NO

1NC

1NO

1NC

-

-

1NC,1NO

1NC,1NO

2NC

1NC,1NO

2NC

1NC

1NC

2NC,1NO

XD 

XF 

XG 

XH 

VA 

VB 

VC 

VD 

VF 

VG 

VJ 

DD 

XB 

XJ 

TA 

TB 

TC 

TD 

TF 

TG 

TJ 

Rear Unlock Button

CAUTION

Solenoid lock type

• This safety switch is designed to lock the actuator while the solenoid is energized 

and to release it when deenergized.

• When the power to the solenoid is interrupted by accident, such as disconnection, 

the lock is released before a machine stops ompletely. Then, the worker may be 

exposed to hazards. 

• This safety switch can be used only for limited applications which do not especially 

need to be locked for safety.

Fzh  

 =

maximum force (F1max)

Safety coefficient (=1 3)

Applicable Standards

Applicable Directives

Thermal Current ‹th›

Contact Ratings

(Reference Values)

‹Ue, Ie›*2

Rated Operating Voltage
Rated Current
Turn ON Voltage
Turn OFF Voltage
Rated Power Consumption
Rated Operating Voltage
Rated Current
Light Source

llumination Color

Standards for Use

Solenoid

Indicator

Operating Condition

Inpulse withstand voltage

‹Uimp›

Raed Insulation voltage‹Ui›

Interlocking device Type

/ the level of coded

Device

Short-circuit Protective

current

Conditional short circuit

Degree of Protection

Contact Resistance

Direct Opening Force

Direct Opening Travel

when Locked

Actuator Tensile Strength

Electrical Durability

Mechanical durability

B10d

Operating Speed

Operating Frequency

Class of Protection

DC24V  100%  duty  cycle

200 mA (initial value)

Rated voltage x 85% maximum (at 20°C)

Rated voltage x 10% minimum (at 20°C)

Approx. 5W

DC24V 100% duty cycle

10 mA

LED

Green

Type 2 Interlocking device

/ low level coded actuator (EN ISO / ISO14119)

EN ISO / ISO14119, IEC60947-5-1, EN60947-5-1, 

GS-ET-19,UL508, CSA C22 2 No.14, GB 14048. 5

IEC60204-1/EN60204-1

Low Voltage Directive, Machinery Directive

2.5A

AC  Resistive load (AC12)

 

Inductive load (AC15)

DC  Resistive load (DC12)

 

Inductive load (DC13)

 30V 

125V  250V

 - 

2.5A  1.5A

 - 

1.5A  0.75A

 2.5A 

1.1A 

0.55A

 2.3A 

0.55A  0.27A

Class

 II

 (IEC61140) *3

900 operations/hour

0.05 to 1.0 m/s

2,000,000 (ISO 13849-1 Annex C Table C.1)

2,000,000 operations minimum (GS-ET-19)

The Rear Unlock Button: 3000 operations

minimum (Type HS5L-

L)

100,000 operations min. (AC-12 250V/1.5A)

2,000,000 operations min. (AC/DC 24V 100mA)

(900 operations / hour)

Fzh=1,400N minimum   

F1max=1820N minimum (GS-ET-19)  *4, *5

(Fzh=500N minimum: HS9Z-A55 actuator)   
11 mm minimum (actuator: HS9Z-A51,A5P)

12 mm minimum (for other actuators)

120N minimum

50 m

Ω maximum (initial value)

IP67 (IEC60529) , Type 4X Indoor Use Only
50A(250V)

Use 250V / 10A fast acting type fuse *6

Operating Temperature

Operating Humidity

Pollution Degree

Altitude

2.5kV (Between ground and  LED, solenoid circuit : 0.5kV)

250V (Between ground and LED, solenoid circuit : 30V) 

-25 to +55°C (no freezing)

20 to 95%RH (no condensation)

3 (Inside 2)

2000m maximum

Thank you for purchasing this IDEC product. Confirm that the delivered product is 

what you have ordered. Read this instruction sheet to make sure of correct operation.

In this operation instruction sheet, safety precautions are categorized in order of 

importance to Warning and Caution :

Warning notices are used to emphasize that improper operation may cause severe 

personal injury or death.

Caution notices are used where inattention might cause personal injury or damage to 

equipment.

INSTRUCTION SHEET

Original Instructions

Solenoid Type Safety Switch

HS5L Series

S A F E T Y   P R E C A U T I O N S

CAUTION

WARNING

*In order to verify if the 

product you are interested in 

is certified with the S mark, 

please check the following 

section on our website: "List 

of type numbers certified 

with the S mark"

*

Shock Resistance

Vibration Resistance

Operating Extremes: 100m/s

2

, Damage Limits: 1000m/s

2

Operating Extremes:10 to 55 Hz, half amplitude 0.35mm 

Damage Limits: 30 Hz, half amplitude 1.5mm

Conduit Cover

 

M : Standard type (M20)

  SM : Cable side-routed type (M20)

Содержание HS5L Series

Страница 1: ...ON Voltage Turn OFF Voltage Rated Power Consumption Rated Operating Voltage Rated Current Light Source llumination Color Standards for Use Solenoid Indicator Operating Condition Inpulse withstand vol...

Страница 2: ...compatibility of plastic material and Loctite into consideration HS9Z A52 HS9Z A52 Mounting centers 12 mm Mounting centers 20 mm HS9Z A53 HS9Z A55 R1 230 mm 230 mm 310 mm 70 mm Horizontal Swing R2 260...

Страница 3: ...ISO13849 1 will be reduced due to the restricted error detection under certain circumstance The insulation of the cable has to withstand environmental influences The entire concept of the control sys...

Страница 4: ...tor turns on when solenoid is energized CAUTION Install the HS5L to ensure that a worker can operate the rear unlock button from inside the safety hedge the dangerous area It is dangerous to install t...

Страница 5: ...river Tip shape of the driver is according to the standard of DIN5264 0 4 7 to 13 2 5 2 5 How to open conduit port cable side routed type Before use knock in the conduit port where the connector is to...

Страница 6: ...cuit Safety relay module HR1S AF series manufactured by IDEC CORPORATION HS9Z A51 Actuator HS5L VB4 Safety Switch with Solenoid Used as open close monitor of guard Guard Open 12 11 24 23 Example of a...

Страница 7: ...7 21 5 27 3 M4 20 to 22 10 to 11 3 6 40 33 20 30 30 9 27 7 7 21 5 106 14 9 3 M4 20 to 22 10 to 11 41 5 42 2 20 29 6 36 2 20 28 86 5 127 20 35 1 1 41 6 2 5 2 9 44 5 30 30 27 21 5 7 7 9 10 24 6 5 24 5...

Страница 8: ...rews C D 20 12 2 4 3 2 10 2 9 0 8 2 0 8 8 5 15 8 15 30 2 M4 4 3 or M4 tapped when installed on the door 5 When installed on the door 39 7 When installed on the door 11 2 Rubber Cushions Washer Supplie...

Отзывы: