Note : To unwire the terminals, disassemble the product in the following order:
turn off the power → loosen connecter B → remove the terminal cover →
remove the waterproof gasket from connecter A* → loosen connecter A
* Please remove the water-proof gasket carefully with tools such as tweezers.
Be careful when removing the gasket as damages may affect its waterproof
properties. Also, loosening connecter A without removing the gasket first may
damage the cable and provoke connection issues. Please make sure you
re-insert the waterproof gasket properly into connector A when re-assembling
the product.
7
Example of wiring Diagram realizing Safety Category
S1: HS5L-VB4 Safety Switch with Solenoid
S2: Starting Switch (HW Series Momentary)
S3: Unlocking Enabling Switch
S4: Safety limit Switch
ESC: Outside start condition
K3, 4: Safety Contactor
F1: Outside fuse of safety relay module at power supply line
Note: Use he monitoring device(Safety relay module) provided he capavility to
detect a cross short circuit. The insulation of the cable has to withstand
environmental influences. If a control device other than he one shown in the
draft is used, the used control device has to be equipped with a cross short
circuit monitor.
Example of a circuit diagram for Safety Category 4
(attainable PL = e)
L1(+)
DC24V
S3
F1
K4
K3
N(−)
DC0V
A1
(−)
A2(+)
52
S1
13
14
ESC
K4
K3
S2
51
42
41
S33
S34
13
23
A1
S11
S22
14
24
A2
S12 S21
Output Circuit
HR1S-AF Safety relay module
One of the example of
the circuit ; Safety
relay module, HR1S-AF
series manufactured
by IDEC CORPORATION
HS9Z-A51 Actuator
HS5L-VB4
Safety Switch with Solenoid
Used as open/close
monitor of guard
Guard Open
12
11
24
23
L1(+)
DC24V
S3
F1
K4
K3
N(−)
DC0V
A1
(−)
A2(+)
52
S1
13
14
ESC
K4
K3
S2
51
42
41
S4
1
2
S33
S34
13
23
A1
S11
S22
14
24
A2
S12 S21
Output Circuit
HR1S-AF Safety relay module
One of the example of
the circuit ; Safety
relay module, HR1S-AF
series manufactured
by IDEC CORPORATION
HS9Z-A51 Actuator
HS5L-VB4
Safety Switch with Solenoid
Used as open/close
monitor of guard
Guard Open
12
11
24
23
Example of a circuit diagram for Safety Category 3
(attainable PL = d)
(Condi ion 1: To apply he fault exclusion of mechanical structural parts including he actuator
→ Make sure to use the product within the product specification range described in this
manual and the version of the manual provided with the product.)
(Condi ion 2: Documentation of he reason for he machine/equipment manufacturer to have
applied the fault exclusion based on ISO13849-1, ISO13849-2 or IEC62061 )
A
B
Safety Switch Terminal Cover
Gasket
Connecter
(To buy separately)
The waterproof
gasket is completely
tightening the cable
The waterproof
gasket is not
properly tightening
the cable
Spring Force
Terminal
Spring Force
Terminal
Safety
Switch
A
Gasket
Sheath
B
Terminal
Cover
CAUTION
• Make sure not to lose any screw when
removing the terminal cover from the
switch.
• Please make sure the cable is insterted
deep enough into the terminal cover so
that the waterproof gasket can tighten
he cable sheath completely and ensure
its waterproof functions.
• Make sure you always tighten connect-
er A before connecter B, otherwise the
wires which connect the terminals might
get twisted or might break, and this
might also damage the terminal ports.
• When tightening the connecters, only
use a tightening torque that is approved by the connecters' manufacturer to
ensure waterproof properties of the product.
• Do not pull or twist the cable with excessive force, otherwise you might damage
he wires inside of it.
A
B
Connecter (To buy separately)
Gasket
1. Loosen connecter A and connecter B, and insert the cable into these pieces in the
following order :
connecter B → waterproof gasket → connecter A.
Do not tighten the connecters yet.
2. Remove the terminal cover from the switch
and insert the cable into the cover.
3. Wire the terminals.
4. Tighten connecter A into the terminal cover.
Fix the terminal cover back into its original
position. Tighten connector B.
Connecters' mounting method