Introduction
1-4
Service Manual
WARNING:
To ensure accurate performance and prevent device failure, do not subject to
extreme moisture, such as direct exposure to rain. Such exposure may cause
inaccurate performance or device failure.
WARNING:
The monitoring screen contains toxic chemicals. Do not touch a broken
enclosure or monitoring screen. Physical contact with a broken enclosure or
monitoring screen can result in transmission or ingestion of toxic substances.
WARNING:
No user serviceable parts inside.
1.3.3
Cautions
Caution:
Federal law (U.S.A.) restricts this device to sale by or on the order of a
physician.
Caution:
When connecting the monitoring system to any instrument, verify proper
operation before clinical use. Both the monitoring system and the instrument
connected to it must utilize a grounded outlet. Any equipment connected to
the data interface must be certified according to the latest IEC/EN 60950 -1
standard for data-processing equipment, the latest IECEN 60601-1 standard
for electromedical equipment, or the latest IEC/EN safety standards relevant
to that equipment. All combinations of equipment must be in compliance
with Requirements for Medical Electrical Systems IEC Standard
60601-1:2007and the electromagnetic compatibility IEC/EN Standard
60601-1:2005. Anyone who connects equipment to the data interface is
configuring a medical system and, therefore, is responsible for ensuring that
the system complies with the Requirements for Medical Electrical Systems
IEC/EN Standard 60601-1-1:2007 and the electromagnetic compatibility IEC/
EN Standard 60601-1-2:2007. Accuracy may degrade if it is connected to
secondary I/O devices when the equipment is not connected to earth
reference.
Содержание Nellcor GR101704
Страница 1: ...Service Manual Nellcor Bedside Respiratory Patient Monitoring System...
Страница 8: ...Page Left Intentionally Blank vi...
Страница 32: ...Page Left Intentionally Blank 2 14 Service Manual Product Specifications...
Страница 46: ...Page Left Intentionally Blank 3 14 Service Manual Theory of Operations...
Страница 54: ...Page Left Intentionally Blank 4 8 Service Manual Product Overview...
Страница 96: ...Operation 6 34 Service Manual a Press an alternate menu option b Press EXIT AND RESTART to exit SERVICE MODE...
Страница 114: ...Page Left Intentionally Blank 7 18 Service Manual Trend Data Access...
Страница 120: ...Page Left Intentionally Blank 8 6 Service Manual Performance Considerations...
Страница 168: ...Page Left Intentionally Blank 10 46 Service Manual Modification and Testing...
Страница 192: ...Repair 12 4 Service Manual Figure 12 2 Exploded View of Internal Components...
Страница 232: ...Page Left Intentionally Blank 12 44 Service Manual Repair...
Страница 235: ......