Troubleshooting
11-4
Service Manual
11.3
User Prompts and Messages
Prompts require a response from or action by the caregiver.
11.4
Alarms and Error Conditions
This section covers alarms and correctable error conditions. Reference
, p. 11-19, for non-correctable errors.
11.4.1
Alarms
The status field at the top of the monitoring screen contains information
describing overall monitoring system status and any active alarms. If multiple
alarms occur during user interaction with a menu or dialog box, the list of
alarm messages collapses to a single line listing the total number of alarms cur-
rently active. Cancellation or dismissal of an alarm message requires user inter-
vention, whereas status messages do not. The message identifies the alarm or
status. If it is an alarm, it offers users a MORE INFO button, which when
pressed, provides detailed data and a means to correct the situation or clear
the alarm. Press DISMISS ALARM to clear the alarm if that is an option. If it is
not an option, take the recommended action. If that does not clear the alarm,
reset it. If a reset does not clear the alarm, return it for service.
Note:
Not all high-priority alarms have a DISMISS ALARM option. These are serious errors
and require the user to resolve the issue or return the monitoring system to Covidien
or a qualified service technician.
Table 11-1.
Common User Prompts and Messages
Priority
Message
Condition
Resolution
Dismiss
---
Ready: Attach
sensor to
patient and
monitor
Awaiting patient connection
to begin monitoring
Connect the interface cable to the
sensor port and the appropriate
sensor to the interface cable and
to the patient.
---
---
Monitoring
Proper connection established,
patient monitoring in progress
None.
---
Содержание Nellcor GR101704
Страница 1: ...Service Manual Nellcor Bedside Respiratory Patient Monitoring System...
Страница 8: ...Page Left Intentionally Blank vi...
Страница 32: ...Page Left Intentionally Blank 2 14 Service Manual Product Specifications...
Страница 46: ...Page Left Intentionally Blank 3 14 Service Manual Theory of Operations...
Страница 54: ...Page Left Intentionally Blank 4 8 Service Manual Product Overview...
Страница 96: ...Operation 6 34 Service Manual a Press an alternate menu option b Press EXIT AND RESTART to exit SERVICE MODE...
Страница 114: ...Page Left Intentionally Blank 7 18 Service Manual Trend Data Access...
Страница 120: ...Page Left Intentionally Blank 8 6 Service Manual Performance Considerations...
Страница 168: ...Page Left Intentionally Blank 10 46 Service Manual Modification and Testing...
Страница 192: ...Repair 12 4 Service Manual Figure 12 2 Exploded View of Internal Components...
Страница 232: ...Page Left Intentionally Blank 12 44 Service Manual Repair...
Страница 235: ......