6-27
Cisco TelePresence System Release 1.5 Administrator Guide
OL-13676-04
Chapter 6 Troubleshooting the CTS 1100
Managing Hardware Setup
Related Information
For more information about setting up and testing presentation devices, see the
Cisco TelePresence System 1100 Assembly, Use & Care, and Field Replacement Unit Guide
.
For more system troubleshooting information, see the
Cisco TelePresence System Troubleshooting
Guide
on Cisco.com.
System Status window shows
unexpected Document Camera
status.
Document camera settings may
need to be adjusted in
Cisco Unified CM.
Cisco recommends setting the Digital Visual Interface
(DVI) resolution to XGA/60 at 1024 x 768/60 Hz. See
the Optional Hardware section of the
Cisco Unified
Communications Manager Configuration Guide for the
Cisco TelePresence System
for more information.
Tip
Presentation devices automatically shut off when there is no longer a video signal to that presentation device. An
on-screen timer counts down the remaining time to shut-down. The amount of time that it takes a device to shut down
depends on your Cisco Unified CM configuration. Most CTS devices that support
PiP
shut down in 10 to 15 seconds
after the video signal is removed. Devices on the CTS 3000 and CTS 3200 series that have black boxes associated
with the auxiliary control take 5 minutes to shut down. See the Product Specific Configuration Layout section of the
Cisco Unified Communications Manager Configuration Guide for the Cisco TelePresence System
for more
information about controlling presentation devices and associated displays.
Table 6-7
Troubleshooting Presentation Devices
Problem
Possible Cause
Possible Solution