7-44
Cisco TelePresence System Release 1.6 Administration Guide
OL-13676-04
Chapter 7 Troubleshooting the CTS 1300
Managing Hardware Setup
•
Use the top two screws for left and right adjustment.
•
The lower screw for up and down adjustment.
•
The screws in the middle for adjustments on the horizontal plane (rotational).
Figure 7-41
Camera Adjustment Screws
Step 6
Adjust the camera zoom by completing the following steps:
a.
Loosen the thumbscrew for the zoom ring on the camera lens.
Note
The zoom ring is labeled “W-T.”
b.
Adjust the camera zoom so that the black curved line on the left of the target touches the left edge
of the display screen, as shown in
Figure 7-42
.
Note
Because of the position of the target, the target appears smaller and not parallel to the camera.
This view is normal. Participants will appear lifelike after you complete the testing procedure.
c.
After you adjust the zoom, make any required adjustments to the focus with the focus ring.
Right
adjust
screw
Left
adjust
screw
Up/down
adjust
screw
Side to side
adjust screw
Side to side
adjust screw
Up/down
adjust
screw
206130