6-6
Cisco TelePresence System Release 1.5 Administrator Guide
OL-13676-04
Chapter 6 Troubleshooting the CTS 1100
Managing Hardware Setup
Testing the CTS 1100 Camera
The camera is set up successfully when the image is centered and in focus on the display screen, and the
white balance is configured. The hardware setup software provides a camera Auto Adjust feature and
uses targets to adjust the camera zoom and fine-tune the camera focus.
To set up the CTS 1100 camera for testing, complete the tasks in the following sections:
•
Removing the Camera Cover and Leveling the Camera
•
Attaching the Large Camera Target to the Easel
•
Positioning the Table and Starting the Calibration Procedure
•
Managing Focus Adjustments and Adjusting the Camera Zoom, page 6-9
•
Focusing the Camera
•
Saving Your Settings
•
Attaching the Camera Lens and Hood
Removing the Camera Cover and Leveling the Camera
The camera cluster must be perfectly level for you to properly configure the camera. To level the camera,
complete the following steps.
Step 1
Turn the four black plastic screws on the top and bottom of the camera assembly 1/4 turn, then remove
the camera cover, as shown in
Figure 6-2
.
Figure 6-2
Removing the Camera Cover
Step 2
Place the small
spirit level
on top of the camera assembly and adjust the leveling screws behind the
camera cluster until the camera assembly is level, as shown in
Figure 6-3
.
206623
Cover
release
screws
Cover
release
screws