7-29
Cisco TelePresence System Release 1.6 Administration Guide
OL-13676-04
Chapter 7 Troubleshooting the CTS 1300
Managing Hardware Setup
Step 7
Click Done to complete the right camera focusing procedure.
Focusing the Right Camera
Note
If you logged out of the GUI, you must re-select the correct table type after you log in; otherwise, you
could configure your system for the incorrect table type. To select the correct table type, complete
Step 5
in the
“Positioning the Table and Starting the Calibration Procedure” section on page 7-51
.
To focus the right camera, follow these steps:
Step 1
In the Cisco TelePresence Administration window, click the Right radio button.
Step 2
Click the Setup button that is located below the center screen icon.
Step 3
Click Show Focus Targets.
Step 4
Position the small camera target by completing the following steps:
a.
Place the target on the table one foot from the edge where the participants sit.
b.
Position the target so that the patterns on the target are enclosed in the green box.
Step 5
Position the large target by completing the following steps:
a.
Remove the large focus target from the easel.
b.
Rotate the target 90 degrees.
c.
Have another person hold the target upright.
Note
If another person is not available, clamp the top of the target into the clamp at the top of the easel.
d.
Place the top of the easel five feet behind the top of the small target.
e.
Position the target so that the topmost patterns are enclosed in the red box.
Figure 7-25
shows the large and small target positions.