Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
SGNL-C-M
Dis ARCDAT screen C M-patch current VL
Lv.2 Details
To display the current M-patch value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-C-K
Dis ARCDAT screen C Bk-patch current VL
Lv.2 Details
To display the current Bk-patch value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-C-C
Dis ARCDAT screen C C-patch current VL
Lv.2 Details
To display the current C-patch value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
DLTA-A-Y
Dis of ARCDAT screen A Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-A-M
Dis of ARCDAT screen A M-density differ
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-A-C
Dis of ARCDAT screen A C-density differ
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
COPIER > DISPLAY > HT-C
DLTA-A-K
Dis of ARCDAT screen A Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-B-Y
Dis of ARCDAT screen B Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-B-M
Dis of ARCDAT screen B M-density differ
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-B-C
Dis of ARCDAT screen B C-density differ
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-B-K
Dis of ARCDAT screen B Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...