Parts Replacement and Cleaning > Image Formation System > Reinstalling the ITB > Procedure
Parts Replacement and Cleaning > Image Formation System > Reinstalling the ITB > Procedure
Reinstalling the ITB
■
Preparations
1) Open the Front Cover, Right Lower Cover and Right Upper Cover.(Refer to page 4-104)
2) Remove the ITB Cover.(Refer to page 4-104)
3) Remove the ITB Unit.(Refer to page 4-105)
4) Remove the ITB Cleaning Unit.(Refer to page 4-109)
5) Remove the ITB.(Refer to page 4-113)
■
Procedure
CAUTION:
Be careful not to make mistakes when installing since there is no compatibility between
the ITB Unit of iR-ADV-C52XX series and that of iR-ADV-C50XX series.
1) Check that the ITB Sub Pressure Release Lever is in the below position.
ITB sub pressure release lever
2) Stand the ITB Unit on the ITB Cover.
• 2 claws
x2
ITB cover
Claws
Claw
F-4-170
F-4-171
NOTE:
Cover the ITB Installation Auxiliary Sheet included in the package as shown in the
figure. (Place the slant area to the ITB Motor side.) The framed area is the area where
the ITB is easily damaged, so be sure that the area is covered with the ITB Installation
Auxiliary Sheet. After installing the ITB, remove the ITB Installation Auxiliary Sheet.
Slant Area
Mold is covered
with the sheet
F-4-172
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...