2
2
2-137
2-137
Technology > MEAP > Installing an MEAP Application > Resource Information
Technology > MEAP > Installing an MEAP Application > Resource Information
■
Resource Information
●
Outline
Application Management page shows [ resource information ] for information of the whole
device resources including Amount Used, Remaining, and Percent Used.
This function enables users to judge the remaining resources before installing the additional
application. Such resource information is shown based on the manifest header stated at the
top of each application, which declares the resources required in the application. Therefore,
the information does not necessarily show the resources actually in use.
The following resource information is shown:
• Storage
• Memory
• Thread
• Socket
• File Descriptor
If the hard disk does not have enough free space for the application, the application cannot
be installed.
Moreover, if the free space of any of the resources (Memory, Thread, Socket, and File
Descriptor) is insufficient, the application cannot be started.
The following procedure shows how to check the resource information.
1) Log in to SMS.
2) Click [ MEAP Application Management ].
3) Check [ Resource Information ] for information of the whole device resources.
F-2-203
●
Device's resources
When 1 MEAP application operates, the resource volume allocated to each device is as
follows (loaded resource list). Since the following value is an estimate, when installing the
MEAP applications, it needs to check the available resource of SMS.
Since the indication of SMS resource volume fluctuates by the login service (authentication
function) and configuration (future model), which the user selected, it may show a bigger
value than the following values.
List of Available Resources
Product Name
Storage Memory Thread Socket File Description
iR-ADV C5051 series
1024MB 128MB
256
256
256
iR-ADV C9075 series
1024MB 128MB
256
256
256
iR-ADV 6075 series
1024MB 128MB
256
256
256
iR-ADV 8105 PRO series
1024MB 128MB
256
256
256
iR-ADV C2030/C2020 series Flash model 220MB
32MB
162
128
128
HDD model 1024MB 128MB
256
256
256
iR-ADV 4045 series
1024MB 128MB
256
256
256
iR-ADV C5255 series
1024MB 128MB
256
256
256
Note:
• Among the resources, the free space of Storage is checked when installing an application.
For other resources, the free space is checked when the application is started.
• Some applications call for a specific set of conditions for installation. For details, see the
User’s Guide that comes with the individual applications.
• Maximum installable application is up to 20 even if the remaining resource is adequate.
(However, the Send function consumes 1, it must be 19 in practice.) Authentication
application is not included in this number.
• The MEAP application, which can be started simultaneously, is up to 19. (Authentication
application is not included in this number.)
CAUTION:
To install an application, the user needs to use the following URL when accessing the
license control system to obtain a license file. In doing so, he/she needs to register the
license access number of the application and the serial number of the device.
http://www.canon.com/lms/license/
T-2-83
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...