7
7
7-4
7-4
Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
Error Code
Error Code Details
E
code
Detailed
code
Occurance
area
Items
Description
E001 0000
05
Title
Abnormal high temperature in Main Thermistor 1, 2
Description Main Thermistor 1, 2 (TH1) detects 260 deg C or more for
0.2 sec.
Remedy
1. Go through the following: DISPLAY > ANALOG >
FIX-C, or DISPLAY > ANALOG > FIX-E; if it’s less than
260 deg C, go through the following to clear the error:
COPIER>FUNCTION>CLEAR>ERR; and then turn OFF/
ON the power.
It it’s 260 deg C or more, do not turn on the power before
replacing the Film Unit.
2. Replace the Film Unit.
3. Replace the Shutter Unit.
4. Replace the DC Controller PCB (UN1).
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
E001 0001
05
Title
Abnormal high temperature in Sub Thermistor 1, 2
Description Sub Thermistor 1, 2 (TH1) detects 275 deg C or more for
0.2 sec.
Remedy
1. Go through the following: DISPLAY > ANALOG >
FIX-E2 or DISPLAY > ANALOG > FIX-E3; if it’s less than
275 deg C, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR; and then turn
OFF and then ON the power.
If it’s 275 deg C or more, do not turn on the power before
replacing the Film Unit.
2. Replace the Film Unit.
3. Replace the Shutter Unit.
4. Go through the following to check drive of FM5 and
FM6: COPIER > FUNCTION > PART-CHK > FAN; if not
working properly, replace the fan.
5. Replace the DC Controller PCB (UN1).
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
E
code
Detailed
code
Occurance
area
Items
Description
E001 0003
05
Title
High temperature error detected by hardware
Description Hardware detects abnormal high temperature of the
Thermistor (Main Thermistor 1: 264 deg C, Main
Thermistor 2: 265 deg C, Sub Thermistor 1, 2: 280 deg C)
for 400 msec consecutively.
Remedy
1. If the detected temperature of the Thermistor is
less than the abnormal high temperature specified for
Thermistor, go through the following to clear the error:
COPIER > FUNCTION > CLEAR > ERR; and then turn
OFF and then ON the power.
If it’s at abnormally high temperature, do not turn on the
power before replacing the Film Unit.
2. Replace the Film Unit.
3. Replace the Shutter Unit.
4. Go through the following to check drive of FM5 and
FM6: COPIER > FUNCTION > PART-CHK > FAN; if the
not working properly, replace the fan.
5. Replace the DC Controller PCB (UN1).
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
E003 0000
05
Title
Error detected when the Heater is ON
Description After the Heater was turned ON, Main Thermistor 2, Sub
Thermistor 1 or Sub Thermistor 2 detects 21 deg C or
more and 50 deg C or less for 3 sec.
Remedy
1. Go through the following to clear the error: COPIER
> FUNCTION > CLEAR > ERR; and then turn OFF and
then ON the power.
2. Check connection of the Connectors (Thermistor
Connector and AC Connector).
3. Replace the Film Unit.
4. Replace the Shutter Unit.
5. Replace the DC Controller PCB (UN1).
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER >
FUNCTION > CLEAR > ERR.
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...