6
6
6-32
6-32
Troubleshooting > Version upgrade > Version Upgrade via SST > Connection
Troubleshooting > Version upgrade > Version Upgrade via SST > Connection
IP address
:
172.16.1.100
Subnet mask
:
255.255.255.0
IP address
:
172.16.1.160
Subnet mask
:
255.255.255.0
Cross cable
10Base-T
:
Category 3, 5 or later
100Base-TX
:
Category 5 or later
1000Base-TX
:
Category 5 (CAT5e) or later
Steps
1) Use the cross cable to connect the machine to the PC with SST installed.
2) Turn on the main power switch of this machine.
3) Enter Service mode to start the machine in Download mode.
Select COPIER > FUNCTION > SYSTEM > DOWNLOAD and press [OK].
F-6-36
4) Check the IP address of the PC.
Go to Start menu to select Program > Accessory > Command Prompt.
Type IPCONFIG and press [Return] to see the network settings of the PC.
If any discrepancies from the description in the figure below are found, change the network
settings of the PC.
CAUTION:
The network settings are not shown with IPCONFIG if the PC is disconnected from
the network. To check the settings, connect the PC to this machine at power-on by the
cross cable.
F-6-37
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...