7
7
7-52
7-52
Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
E
code
Detailed
code
Occurance
area
Items
Description
E602 0001
00
Title
Error in HDD
Description HDD failed to be recognized. Startup partition (BOOTDEV)
failed to be found at startup.
Remedy
1. Turn OFF the main switch and check connection of
HDD cable, and then turn ON the main switch.
2. If the Encryption Board has been installed, there may
be an Encryption Board failure. In this case, disconnect
the signal cable connecting to the Encryption Board and
directly connect to the HDD. (It cannot be connected
from the back side. Open the Main Controller Cover, and
connect by going over the Main Controller PCB 1.) After
connecting, power on by the safe mode. If the machine
starts normally, replace the Encryption Board as the
Encryption Board had failed.
3. Be sure that HDD spins stably (no problem in drive
sound) and 5V/12V power is supplied when the main
power is turned ON. (If the drive sound is abnormal,
replace the HDD.)
4. Replace the HDD and reinstall the system. (In the case
of using a USB memory device, insert a USB memory
device where the system software has been registered to
the slot of the host machine, and then execute main menu
[3]: Upgrade (Overwrite all).)
5. Replace the Main Controller PCB 1.
E602 0002
00
Title
Error in HDD
Description There is no system for the main CPU
Remedy
1. Start in Safe Mode, then perform overall format using
SST or USB memory and reinstall the system, and then
turn OFF and then ON the Main Switch. (Prepare the USB
memory which system software was registered. Insert
the USB memory to the equipment. Execute [3]: Upgrade
(Overwrite All) in the main menu.)
2. If the above measures do not solve the problem, it can
be caused by failure with HDD; therefore, replace the
HDD and reinstall the system.
E
code
Detailed
code
Occurance
area
Items
Description
E602 0003
00
Title
Error in HDD
Description WriteAbort was detected with BootDevice
Remedy
1. Execute detection and recovery of WriteAbortSector
<In the case of display of B/W E-code>
1-1. Perform the following steps because Service Mode is
not available.
1-2. Turn OFF the power. Then, while pressing 1+9 keys,
turn ON the power. WriteAbortSector recovery routine is
automatically started which makes the screen black.
1-3. After a while, progress is displayed because the
process takes time (40 to 50 min.). The process is
complete when the screen turns white.
<In the case of official display of wrench-mark>
1-1. Set as follows: CHK-TYPE=0; and execute HD-
CHECK (40 to 50 min.), and then turn OFF and then ON
the main switch.
2. If the above measures do not solve the problem, start
up in Safe Mode to perform overall format using SST or
USB memory and reinstall the system, and then turn OFF
and then ON the main switch.
3. If no improvement is found despite the above measures,
it can be caused by failure with HDD; therefore, replace
the HDD and reinstall the system.
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...