8
8
8-186
8-186
Service Mode > COPIER > OPTION > IMG-FIX
Service Mode > COPIER > OPTION > IMG-FIX
COPIER > OPTION > IMG-FIX
FN-ENTMP
Set of Fixing Cooling Fan ON/OFF temp
Lv.1 Details
To set the ON/OFF temperature of the Fixing Cooling Fan (Front)/
(Rear).
As the value is incremented by 1, the temperature changes by 5 deg C.
Use case
When offset/fixing failure occurs on the edge of small size paper
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-4 to 4
-4: -20 deg C, -3: -15 deg C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1:
5 deg C, 2: 10 deg C, 3: 15 deg C, 4: 20 deg C
Unit
deg C
Default value
0
FLYING
ON/OFF of flying start temperature ctrl
Lv.2 Details
To set ON/OFF of flying start temperature control.
When 1 is set, flying start temperature control is not performed.
Selecting 1 has an advantage over selecting 0 in terms of the life of
the Fixing Assembly.
Use case
When preferring to extend the life of the Fixing Assembly However,
selecting 1 does not always extend the life.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When 1 is set, FPOT becomes longer.
Display/adj/set range
0 to 1
0: ON, 1: OFF
Default value
0
TMP-TBL7
Fixing control temperature:Plain paper 2
Lv.1 Details
To set the offset of fixing control temperature for plain paper 2 (82 to
105 g/m2).
As the value is incremented by 1, the control temperature is increased
by 5 deg C from the specified value.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on plain paper 2
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
COPIER > OPTION > IMG-FIX
TMP-TBL8
Fixing control temperature:Transparency
Lv.1 Details
To set the offset of fixing control temperature for transparency.
As the value is incremented by 1, the control temperature is increased
by 5 deg C from the specified value.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on transparency
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
TMP-TBL9
Fixing control temperature:Coated paper1
Lv.1 Details
To set the offset of fixing control temperature for coated paper 1 (106
to 163 g/m2).
As the value is incremented by 1, the control temperature is increased
by 5 deg C from the specified value.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on coated paper 1
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
TMP-TB10
Fixing control temperature:Coated paper2
Lv.1 Details
To set the offset of fixing control temperature for coated paper 2 (164
to 220 g/m2).
As the value is incremented by 1, the control temperature is increased
by 5 deg C from the specified value.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on coated paper 2
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...