2
2
2-218
2-218
Technology > Embedded RDS > Error code and strings
Technology > Embedded RDS > Error code and strings
No.
Code
Error strings
Cause
Remedy
29 8xxx 2046 Server certificate
expired
• The route certificate
registered with the device
has expired.
• Certificate other than
that initially registered
in the user’s operating
environment is being used,
but has not been registered
with the device.
• The device time and date
is outside of the certificated
period.
Check that the device time and
date are correctly set.
If the device time and date are
correct, upgrade to the latest
system software.
30 8xxx 2047 Server response
time out
Due to network congestion,
etc., the response from UGW
does not come within the
specified time. (HTTPS level
time out)
If this error occurs when the
communication test is being run
or Service Browser is being set,
try again after a period of time.
31 8xxx 2048 Service not found
There is a mistake in the
UGW URL, and UGW cannot
be accessed. (Path is wrong)
Check that the value of URL of
UGW (RGW-ADR) is https://
a01.ugwdevice.net/ugw/
agentif010.
32 8xxx 2052 URL error
The data which is not URL is
inputted into URL field.
Check that the value of URL of
UGW (RGW-ADR) is https://
a01.ugwdevice.net/ugw/
agentif010.
33 8xxx 2058 Unknown error
SOAP Client fails to obtain
SOAP Response.
Possibility of a problem in
UGW or of a temporary
problem in the network load.
Perform and complete a
communication test (COM-
TEST).
34 8xxx 2063 SOAP Fault
SOAP communication error
has occurred.
Check that the value of port
number of UGW (RGW-PORT)
is 443.
35 xxxx xxxx Device internal
error
An internal error, such as
memory unavailable, etc.,
has occurred during a device
internal error phase.
Turn the device OFF/ ON.
Or replace the device system
software. (Upgrade)
36 xxxx xxxx SUSPEND:
Initialize Failure!
Internal error occurred at the
initiating E-RDS.
Turn the device OFF/ ON.
*1: [Hexadecimal]: indicates an error code returned from UGW.
[Error details in UGW]: indicates error details returned from UGW.
T-2-102
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...