8
8
8-46
8-46
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
■
HT-C
COPIER > DISPLAY > HT-C
TGT-A-Y
Dis of ARCDAT screen A Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-M
Dis of ARCDAT screen A M-color target VL
Lv.2 Details
To display the M-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-C
Dis of ARCDAT screen A C-color target VL
Lv.2 Details
To display the C-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-K
Dis of ARCDAT screen A Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-B-Y
Dis of ARCDAT screen B Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
COPIER > DISPLAY > HT-C
TGT-B-M
Dis of ARCDAT screen B M-color target VL
Lv.2 Details
To display the M-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-B-C
Dis of ARCDAT screen B C-color target VL
Lv.2 Details
To display the C-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-B-K
Dis of ARCDAT screen B Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-C-Y
Dis of ARCDAT screen C Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-C-M
Dis of ARCDAT screen C M-color target VL
Lv.2 Details
To display the M-patch target value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Содержание imageRUNNER ADVANCE C5255
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 310: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts Cleaning Parts ...
Страница 528: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 692: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 821: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...