Triton Analog Trunk GS/LS Properties
7-12
AltiContact Manager Administration Manual
Enable Answer
Debounce (Incoming)
Enables a timeout period of 2 seconds (for ignoring
false CO disconnect signal), after answering an
incoming call.
Loop Break Duration
(ms)
Disconnects signal if CO breaks loop current. You
can set the duration from 200 to 1000 ms.
Tone Disconnect
Busy tone (reorder tone, fast busy tone, error tone,
etc.) or dial tone (continuous tone, etc.). This should
be used in conjunction with drop in loop current. For
COs who cannot guarantee loop break, this may be
the only option.
Receiver/
Transmission Gain
Slide setting adjusts the incoming volume from -6 dB
to 6 dB for every Triton Analog Trunk channel.
The default setting is
0 dB
, and it is highly
recommended that you not change this setting.
Caution:
Setting the volume too high will cause
distortion in voice quality and/or
missed DTMF digits.
Trunk to Trunk Gain
The gain in the Triton analog trunk to Triton analog
trunk connection, in dB.
Last Diagnosis Time
The last time the
Diagnosis
button was clicked.
Diagnose button
Use this button view the Noise Level, Echo Return
Loss, and Hybrid Echo Return Loss, measured using
the current
Impedance
setting. Acceptable range for
Noise Level is less than -67dBm in value. Acceptable
range for Echo Return Loss is less than -12dB. For
example, Noise Level of -72 dB is good and -63 dB
is poor; Echo Return Loss of -19 dB is good and -8dB
is poor.
Noise Level
The noise level (displayed after you click the
Diagnose
button or the
Match Impedance
button).
Echo Return Loss
The measurement for echo return loss (displayed
after you click the
Diagnose
button or the
Match
Impedance
button).
Hybrid Echo Return
Loss
The measurement for hybrid echo return loss
(displayed after you click the
Diagnose
button or the
Match Impedance
button).
Parameter
Description
Содержание AltiContact Manager Version 5.0A
Страница 38: ...xxxvi AltiContact Manager Administration Manual...
Страница 148: ...Stopping the AltiGen Switching Service 4 12 AltiContact Manager Administration Manual...
Страница 182: ...Feature Profiles 5 34 AltiContact Manager Administration Manual...
Страница 216: ...Configuring the Triton T1 E1 PRI Board 6 34 AltiContact Manager Administration Manual...
Страница 314: ...Agent Logout Reason Codes 12 8 AltiContact Manager Administration Manual...
Страница 322: ...13 8 AltiContact Manager Administration Manual...
Страница 388: ...Setting Queue Management Options 15 24 AltiContact Manager Administration Manual...
Страница 442: ...20 4 AltiContact Manager Administration Manual...
Страница 446: ...Application Extension Setup 21 4 AltiContact Manager Administration Manual...
Страница 510: ...About AltiReach Configuration 26 36 AltiContact Manager Administration Manual...
Страница 518: ...Changing TAPI Configuration Parameters 27 8 AltiContact Manager Administration Manual...
Страница 526: ...DINA Manager 28 8 AltiContact Manager Administration Manual...
Страница 546: ...Technical Training B 6 AltiContact Manager Administration Manual...
Страница 558: ...G 12 AltiContact Manager Administration Manual...
Страница 576: ...Index I 18 AltiContact Manager Administration Manual...