Appendix B
369
Key Definitions
Softkeys displayed by pressing the [Display] key
B.
Ke
y De
fin
iti
on
s
Table B-19
Equivalent circuit selection (Select Circ) menu
Key operation:
[Display] - more 1/2 - EQUIV CKT - SELECT CIRCUIT
Softkey
Function
GPIB command
A
|
Selects equivalent circuit A. Equivalent circuit A is generally suitable for the
equivalent circuit analysis of inductors with high core loss.
EQUC CIRA
B
|
Selects equivalent circuit B. Equivalent circuit B is generally suitable for the
equivalent circuit analysis of inductors with high winding resistance or resistors
with low resistance value.
EQUC CIRB
C
|
Selects equivalent circuit C. Equivalent circuit C is generally suitable for the
equivalent circuit analysis of resistors with high resistance value.
EQUC CIRC
D
|
Selects equivalent circuit D. Equivalent circuit D is generally suitable for the
equivalent circuit analysis of capacitors.
EQUC CIRD
E
Selects equivalent circuit E. Equivalent circuit E is generally suitable for the
equivalent circuit analysis of oscillators (vibrators).
EQUC CIRE
CALC PARMS
Has the same function as the CALCULATE PARAMETERS key in Table B-18,
“Equivalent circuit analysis (Equiv Circuit) menu,” on page 368.
CALECPARA
SIMULATE F-CHRST
Has the same function as the SIMULATE F-CHRST key in Table B-18,
“Equivalent circuit analysis (Equiv Circuit) menu,” on page 368.
SIMFCHAR
return
Returns to Table B-18, “Equivalent circuit analysis (Equiv Circuit) menu,” on
page 368.
(N/A)
Table B-20
Equivalent circuit parameter definition (Define Param) menu
Key operation:
[Display] - more 1/2 - EQUIV CKT - DEFINE PARAMETERS
Softkey
Function
GPIB command
R1
Sets a value of equivalent circuit parameter R1.
DEFECR1 <value>
C1
Sets a value of equivalent circuit parameter C1.
DEFECC1 <value>
L1
Sets a value of equivalent circuit parameter L1.
DEFECL1 <value>
C0
Sets a value of current equivalent circuit parameter C0. You can set C0 only
when equivalent circuit E has been selected in Table B-19, “Equivalent circuit
selection (Select Circ) menu,” on page 369.
DEFECC0 <value>
SIMULATE F-CHRST
Has the same function as the SIMULATE F-CHRST key in Table B-18,
“Equivalent circuit analysis (Equiv Circuit) menu,” on page 368.
SIMFCHAR
return
Returns to Table B-18, “Equivalent circuit analysis (Equiv Circuit) menu,” on
page 368.
(N/A)
Table B-21
Display allocation (Disp Alloc) menu
Key operation:
[Display] - more 1/2 - ALLOCATION
Softkey
Function
GPIB command
ALL INSTRUMENT
|
Uses the entire screen as the instrument screen
1
.
DISA ALLI
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......