Appendix B
401
Key Definitions
Softkeys displayed by pressing the [Search] key
B.
Ke
y De
fin
iti
on
s
MKR
®
MAXIMUM
Substitutes the sweep parameter value at the main marker on the current active
trace (A or B) into the partial search range upper limit. In other words, the sweep
range is changed using the current position of the main marker as the new partial
search range upper limit.
MKRTRMAX
MKR
D
®
SEARCH
RNG
Uses the range between the main marker on the current active trace (A or B) and
the
D
marker as the partial search range.
MKRTR
return
Returns to Table B-64, “Search (Search) menu,” on page 397.
(N/A)
1. When the sweep type is not list (list sweep).
Table B-70
Search range (Search Rng) menu (2)
Key operation:
[Search] - SEARCH RANGE MENU
1
Softkey
Function
GPIB command
FULL
|
Selects the mode in which the partial search range is the entire list sweep table.
SEARNG FULL
SEGMENT
Selects the mode in which the partial search range is one specific segment in the
list sweep table.
SEARNG SEGMENT
SEGMENT NUMBER
When a segment is selected as the partial search range, specify a segment
number for partial search.
SEGMNUM <value>
RNG LINE on OFF
Toggles on and off the partial search range border line display to indicate the
borders of the partial search range by two vertical lines on the graph. If the
measurement parameter is COMPLEX Z-Y, you cannot turn on the partial search
range border line display.
SEARLINE {ON|OFF}
return
Returns to Table B-64, “Search (Search) menu,” on page 397.
(N/A)
1. When the sweep type is list (list sweep).
Table B-69
Search range (Search Rng) menu (1)
Key operation:
[Search] - SEARCH RANGE MENU
1
Softkey
Function
GPIB command
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......